Alumaflex™ Type MC AL Feeder THHN/THWN-2 Conductors

1/0 AWG through 900 kcmil AlumaFlex™ THHN/THWN-2 Insulated Singles with 8000 series Triple E™ Aluminum Alloy. Bare AlumaFlex™ Aluminum Alloy Grounding Conductor. UL Listed. 600 Volts. Lightweight Aluminum Interlocked Armor.

Download Category Specifications
PDF Excel Table

Application

Suitable for use as follows:

  • Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
  • Power, lighting circuits.
  • Fished or embedded in plaster
  • Concealed or exposed installations.
  • Environmental air-handling spaces per NEC 300.22 (C).
  • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
  • Installation in cable tray and approved raceways.
  • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
  • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations

Specifications

Select a set of products below for more information:
Conductor Ground Wire
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Size (AWG) Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
3 3
1/0 AWG 1/0 AWG
10 10
50 1.27
4 4
1290 32.77
723 1076
More Options
4 4
1/0 AWG 1/0 AWG
10 10
50 1.27
4 4
1414 35.92
925 1377
More Options
3 3
2/0 AWG 2/0 AWG
12 12
50 1.27
4 4
1276 32.42
706 1050
More Options
4 4
2/0 AWG 2/0 AWG
12 12
50 1.27
4 4
1400 35.58
893 1329
More Options
2 2
3/0 AWG 3/0 AWG
16 16
50 1.27
1/0 1/0
1402 35.61
812 1208
More Options
3 3
3/0 AWG 3/0 AWG
16 16
50 1.27
4 4
1399 35.55
901 1340
More Options
4 4
3/0 AWG 3/0 AWG
16 16
50 1.27
4 4
1614 41.00
1168 1739
More Options
3 3
4/0 AWG 4/0 AWG
19 19
50 1.27
2 2
1590 40.39
1087 1618
More Options
4 4
4/0 AWG 4/0 AWG
19 19
50 1.27
2 2
1739 44.19
1374 2044
More Options
3 3
250 KCMIL 250 KCMIL
22 22
60 1.52
2 2
1735 44.07
1274 1895
More Options
4 4
250 KCMIL 250 KCMIL
22 22
60 1.52
1 1
2033 51.65
1928 2870
More Options
3 3
300 KCMIL 300 KCMIL
35 35
60 1.52
1 1
1843 46.81
1476 2196
More Options
4 4
300 KCMIL 300 KCMIL
21 21
60 1.52
1 1
2022 51.37
1933 2877
More Options
3 3
350 KCMIL 350 KCMIL
35 35
60 1.52
1 1
1942 49.33
1655 2463
More Options
4 4
350 KCMIL 350 KCMIL
35 35
60 1.52
1/0 1/0
2106 53.51
2200 3274
More Options
3 3
400 KCMIL 400 KCMIL
35 35
60 1.52
1 1
2035 51.69
1832 2726
More Options
4 4
400 KCMIL 400 KCMIL
35 35
60 1.52
3/0 3/0
2237 56.82
2491 3707
More Options
3 3
500 KCMIL 500 KCMIL
35 35
60 1.52
1 1
2201 55.92
2179 3243
More Options
4 4
500 KCMIL 500 KCMIL
35 35
60 1.52
250 250
2423 61.54
3026 4503
More Options
3 3
600 KCMIL 600 KCMIL
41 41
70 1.78
400 400
2525 64.16
3125 4650
More Options
4 4
600 KCMIL 600 KCMIL
58 58
70 1.78
400 400
2939 74.67
3767 5607
More Options
3 3
750 KCMIL 750 KCMIL
58 58
70 1.78
1/0 1/0
2620 66.56
3122 4646
More Options
4 4
750 KCMIL 750 KCMIL
53 53
70 1.78
350 350
3196 81.18
4452 6625
More Options
4 4
750 KCMIL 750 KCMIL
53 53
70 1.78
4/0 4/0
2891 73.44
4266 6349

Standards & References

Southwire AlumaFlex™ Type MC Cable with Triple E™ Aluminum Alloy meets or exceeds these requirements:

  • UL 83
  • UL 1569
  • UL 1685
  • Federal Specification A-A59544 (formerly J-C-30B)
  • UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
  • IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
  • NFPA 70 (National Electrical Code), Article 330
  • REACH/RoHS-2 (Chemical Limit) Compliant
  • Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems

Construction

Southwire AlumaFlex™ Type MC Cable with Triple E™ Aluminum Alloy is constructed with Type THHN/THWN-2 conductors rated 90˚ C dry, and a bare equipment grounding conductor. Conductors are AlumaFlex™ AA-8000 series aluminum alloy compact stranded. A binder tape is wrapped over the conductors. Aluminum interlocking armor is applied over the assembly. Conductors also available in High Voltage Colors.