SPEC: 25055

3/C CSA TECK 90 1000V ALUMINUM POWER CABLE SPEC25055

Three Conductor 1000V Multi Conductor, FT4 - Flame Retardancy Rating, Direct Burial, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40ºC Min, 90ºC Max, Rated HL (Hazardous Locations)

Download Category Specifications
PDF Excel Table

Application & Features

For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, hazardous locations or direct buried. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Voltage 1000V CSA / 600V UL.

Specifications

Select a set of products below for more information:
Cond. Size Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Ground Size Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm)
More Options
6 AWG 6 AWG
7 7
0.169 0.43
60 1.52
1x6 1x6
65 1.65
1.089 2.77
55 1.40
1.199 3.05
536 798
472 214.10
8.3 21.08
More Options
2 AWG 2 AWG
6 6
0.268 0.68
60 1.52
1x6 1x6
85 2.16
1.345 3.42
55 1.40
1.455 3.70
818 1217
1194 541.59
10.1 25.65
More Options
1 AWG 1 AWG
8 8
0.298 0.76
80 2.03
1x4 1x4
85 2.16
1.503 3.82
65 1.65
1.635 4.15
1031 1534
1506 683.11
11.4 28.96
More Options
1/0 AWG 1/0 AWG
18 18
0.336 0.85
80 2.03
1x4 1x4
85 2.16
1.583 4.02
65 1.65
1.715 4.36
1144 1702
1900 861.82
12.0 30.48
More Options
2/0 AWG 2/0 AWG
12 12
0.376 0.96
80 2.03
1x4 1x4
85 2.16
1.669 4.24
65 1.65
1.801 4.57
1294 1926
2395 1086.35
12.6 32.00
More Options
3/0 AWG 3/0 AWG
16 16
0.422 1.07
80 2.03
1x4 1x4
85 2.16
1.771 4.50
65 1.65
1.903 4.83
1459 2171
3020 1369.85
13.3 33.78
More Options
4/0 AWG 4/0 AWG
18 18
0.474 1.20
80 2.03
1x4 1x4
85 2.16
1.893 4.81
65 1.65
2.025 5.14
1716 2554
3808 1727.28
14.1 35.81
More Options
500 KCMIL 500 KCMIL
35 35
0.735 1.87
90 2.29
1x1 1x1
115 2.92
2.565 6.52
80 2.03
2.731 6.94
3284 4887
9000 4082.33
19.1 48.51
More Options
750 KCMIL 750 KCMIL
53 53
0.908 2.31
90 2.29
1x1/0 1x1/0
115 2.92
2.937 7.46
80 2.03
3.103 7.88
4318 6426
13500 6123.49
21.7 55.12
More Options
250 KCMIL 250 KCMIL
35 35
0.520 1.32
90 2.29
1x2 1x2
115 2.92
2.099 5.33
65 1.65
2.231 5.67
2104 3131
4500 2041.16
15.6 39.62

* Strand count meets minimum number per ASTM
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Cond. Size DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km)
More Options
6 AWG 6 AWG
0.674 1.00
0.812 1.21
0.051 0.08
More Options
2 AWG 2 AWG
0.267 0.40
0.321 0.48
0.045 0.07
More Options
1 AWG 1 AWG
0.211 0.31
0.254 0.38
0.046 0.07
More Options
1/0 AWG 1/0 AWG
0.168 0.25
0.201 0.30
0.044 0.07
More Options
2/0 AWG 2/0 AWG
0.133 0.20
0.160 0.24
0.043 0.06
More Options
3/0 AWG 3/0 AWG
0.105 0.16
0.126 0.19
0.042 0.06
More Options
4/0 AWG 4/0 AWG
0.084 0.13
0.100 0.15
0.041 0.06
More Options
500 KCMIL 500 KCMIL
0.035 0.05
0.044 0.07
0.039 0.06
More Options
750 KCMIL 750 KCMIL
0.024 0.04
0.031 0.05
0.038 0.06
More Options
250 KCMIL 250 KCMIL
0.071 0.11
0.086 0.13
0.041 0.06

* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.

Standards & References

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1569 Metal-Clad Cables
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  1. Conductor:Class B compact stranded 8000 Series Aluminum.
  2. Insulation:Cross-Linked Polyethylene (XLPE), Color Code: Black and numbered
  3. Grounding Conductors:Uninsulated Aluminum Class B stranded grounding conductor
  4. Assembly:Polypropylene tape
  5. Inner Jacket:Black Polyvinyl Chloride (PVC)
  6. Armor:Aluminum Interlocked Armour (AIA)
  7. Overall Jacket:Black PVC (optional colours available)

Resources

There are no downloadable resources for this product.