SPEC: 44103

4/C CU 2000V EPDM/CPE Type W Industrial Grade Cable 90°C. MSHA Approved SPEC44103

Flexible Copper conductors, Ethylene Propylene Diene Monomer (EPDM) insulation, Single Layer Chlorinated Polyethylene (CPE) Jacket

Download Category Specifications
PDF Excel Table

Application & Features

Southwire Type W cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications per Article NEC 400. Suitable for continuous submersion in water – ideal for submersible pumps. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Not for use as perminant building wiring. Meets FT-5 Flame Test.

Specifications

Select a set of products below for more information:
Cond. Size Cond. Strands Strand Class Conductor Number Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Jacket Thickness (mils) (mm) Jacket Color Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) DC Resistance at 25C (ohms/1000') (ohms/km)
More Options
8 AWG 8 AWG
71 71
I I
4 4
0.145 0.37
60 1.52
155 3.94
BK BK
0.988 2.51
577 859
0.679 1.01
More Options
8 AWG 8 AWG
133 133
I I
4 4
0.145 0.37
60 1.52
150 3.81
BK BK
1.011 2.57
588 875
0.679 1.01
More Options
6 AWG 6 AWG
65 65
I I
4 4
0.186 0.47
60 1.52
145 3.68
BK BK
1.120 2.84
748 1113
0.435 0.65
More Options
4 AWG 4 AWG
112 112
I I
4 4
0.235 0.60
60 1.52
125 3.18
BK BK
1.223 3.11
1054 1569
0.274 0.41
More Options
2 AWG 2 AWG
168 168
I I
4 4
0.290 0.74
60 1.52
145 3.68
BK BK
1.465 3.72
1766 2628
0.172 0.26
More Options
1 AWG 1 AWG
224 224
I I
4 4
0.300 0.76
80 2.03
145 3.68
BK BK
1.654 4.20
1985 2954
0.137 0.20
More Options
1/0 AWG 1/0 AWG
259 259
I I
4 4
0.379 0.96
80 2.03
165 4.19
BK BK
1.729 4.39
2249 3347
0.109 0.16
More Options
2/0 AWG 2/0 AWG
324 324
I I
4 4
0.400 1.02
80 2.03
225 5.72
BK BK
1.874 4.76
2764 4113
0.087 0.13
More Options
3/0 AWG 3/0 AWG
418 418
I I
4 4
0.480 1.22
80 2.03
155 3.94
BK BK
1.890 4.80
3226 4801
0.069 0.10
More Options
4/0 AWG 4/0 AWG
532 532
I I
4 4
0.530 1.35
80 2.03
235 5.97
BK BK
2.199 5.59
3979 5921
0.055 0.08
More Options
350 KCMIL 350 KCMIL
893 893
I I
4 4
0.670 1.70
95 2.41
284 7.21
BK BK
2.968 7.54
7114 10587
0.033 0.05

TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 1650 Standard for Portable Power Cable
  • CSA C22.2 No. 96 Portable Power Cables
  • MSHA Approved
  • RoHS-2 (European Directive 2011/65/EU)

Construction

  1. Conductor:Bare, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B3/B172
  2. Separator Tape:Non-conducting tape applied between the conductor and insulation to facilitate stripping
  3. Insulation:Ethylene Propylene Diene Monomer (EPDM). Color coded black, white, red, green
  4. Fillers:Jute fillers applied as needed to round the cable core
  5. Reinforcement Binder:Reinforcing binder with twine applied over the core
  6. Jacket:Black, flame resistant, thermosetting Chlorinated Polyethylene (CPE)

Resources