Southwire 2000V No Lead NL-EPR/SOLONON Traction Power Cable is suited for use in mass transit and general industry applications where flexibility, fire resistance, and low smoke generation are a concern. May be installed in wet or dry locations in cable trays or raceways. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Resistance to moisture and most oils, acids, and alkalis with an overall durable LSZH XLPO jacket. Meets Flame Spread and Smoke Release requirements of NFPA 130. Rated for 1000 lb/ft maximum sidewall pressure. Alternate constructions available upon request.
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (inches) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
| More Options |
1/0 AWG
1/0 AWG
|
1
1
|
19
19
|
0.362
0.92
|
65
1.65
|
45
1.14
|
0.598
1.52
|
326
485
|
428
637
|
| More Options |
350 KCMIL
350 KCMIL
|
1
1
|
37
37
|
0.641
1.63
|
75
1.91
|
65
1.65
|
0.944
2.40
|
1081
1609
|
1296
1929
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
37
37
|
0.766
1.95
|
75
1.91
|
65
1.65
|
1.063
2.70
|
1544
2298
|
1791
2665
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
91
91
|
0.791
2.01
|
75
1.91
|
65
1.65
|
1.088
2.76
|
1544
2298
|
1798
2676
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
259
259
|
0.850
2.16
|
75
1.91
|
65
1.65
|
1.150
2.92
|
1548
2304
|
1820
2708
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
427
427
|
0.909
2.31
|
105
2.67
|
65
1.65
|
1.271
3.23
|
1610
2396
|
1961
2918
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
61
61
|
0.968
2.46
|
90
2.29
|
65
1.65
|
1.297
3.29
|
2316
3447
|
2650
3944
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
127
127
|
0.968
2.46
|
90
2.29
|
65
1.65
|
1.297
3.29
|
2315
3445
|
2650
3944
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
61
61
|
1.118
2.84
|
90
2.29
|
65
1.65
|
1.446
3.67
|
3088
4595
|
3498
5206
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
127
127
|
1.118
2.84
|
90
2.29
|
65
1.65
|
1.450
3.68
|
3088
4595
|
3468
5161
|
* Thicknesses shown as Minimum Average values
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
| Cond. Size | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
| More Options |
1/0 AWG
1/0 AWG
|
1
1
|
4.8
12.19
|
854
387.37
|
0.102
0.15
|
0.132
0.20
|
0.033
0.05
|
150
150
|
145
145
|
| More Options |
350 KCMIL
350 KCMIL
|
1
1
|
7.6
19.30
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
0.040
0.06
|
310
310
|
350
350
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
8.5
21.59
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
380
380
|
430
430
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
8.7
22.10
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
380
380
|
430
430
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
9.2
23.37
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
380
380
|
430
430
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
10.2
25.91
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
380
380
|
430
430
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
10.3
26.16
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
0.038
0.06
|
475
475
|
535
535
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
10.4
26.42
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
0.038
0.06
|
475
475
|
535
535
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
11.6
29.46
|
8000
3628.74
|
0.011
0.02
|
0.018
0.03
|
0.037
0.06
|
545
545
|
615
615
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
11.6
29.46
|
8000
3628.74
|
0.011
0.02
|
0.018
0.03
|
0.037
0.06
|
545
545
|
615
615
|
* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
* Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.