SPEC: 47210

3/C CU 2000V Type G-GC RHINOFLEXTM CPE Mining Cable 90°C. MSHA Approved SPEC47210

Flexible Copper conductors, Ethylene Propylene Rubber (EPR) insulation, Extra Heavy Duty Two Layer Chlorinated Polyethylene (CPE) Jacket with Optional Reflective Stripes

Download Category Specifications
PDF Excel Table

Application & Features

RHINOFLEXTM Type G-G cable is a heavy-duty cable for use where flexibility and maximum protection is required. For use with all portable, temporary, and permanent power applications such as mobile or stationary mining equipment, shuttle cars, mobile drills, pumps, roof bolters, conveyors, and any portable power where equipment grounding is required, It is ideal for use anytime extra-durable, flexible cable is required. Also suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.

Specifications

Select more options below for part numbers, packaging, and color options:
Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground Check Size Inner Jacket Thickness (mils) (mm) Jacket Thickness (mils) (mm) Approx. OD (inches) (cm) Approx. Weight (lbs/1000') (kgs/km)
More Options
8 AWG 8 AWG
3 3
168 168
0.153 0.39
60 1.52
0.287 0.73
10 10
55 1.40
145 3.68
1.026 2.61
661 984
More Options
6 AWG 6 AWG
3 3
133 133
0.198 0.50
60 1.52
0.336 0.85
10 10
55 1.40
95 2.41
1.050 2.67
789 1174
More Options
4 AWG 4 AWG
3 3
259 259
0.235 0.60
60 1.52
0.388 0.99
10 10
60 1.52
95 2.41
1.190 3.02
1014 1509
More Options
2 AWG 2 AWG
3 3
308 308
0.302 0.77
60 1.52
0.452 1.15
8 8
65 1.65
90 2.29
1.325 3.37
1413 2103
More Options
1 AWG 1 AWG
3 3
385 385
0.347 0.88
80 2.03
0.529 1.34
8 8
70 1.78
120 3.05
1.510 3.84
1724 2566
More Options
1/0 AWG 1/0 AWG
3 3
273 273
0.385 0.98
80 2.03
0.551 1.40
8 8
65 1.65
160 4.06
1.650 4.19
2316 3447
More Options
2/0 AWG 2/0 AWG
3 3
324 324
0.400 1.02
80 2.03
0.594 1.51
8 8
85 2.16
100 2.54
1.636 4.16
2401 3573
More Options
4/0 AWG 4/0 AWG
3 3
532 532
0.550 1.40
80 2.03
0.751 1.91
8 8
80 2.03
135 3.43
2.040 5.18
3715 5529
More Options
250 KCMIL 250 KCMIL
3 3
608 608
0.682 1.73
100 2.54
0.816 2.07
8 8
100 2.54
120 3.05
2.390 6.07
4386 6527
More Options
350 KCMIL 350 KCMIL
3 3
855 855
0.809 2.05
100 2.54
0.926 2.35
8 8
100 2.54
125 3.18
2.680 6.81
5801 8633

TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Cond. Size DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km) Rated Strength (lbs) (kg) Min. Bend Radius (in) (cm) Allowable Ampacity In Air 90C
More Options
8 AWG 8 AWG
0.715 1.06
0.903 1.34
0.036 0.05
112 50.80
8.2 20.83
59 59
More Options
6 AWG 6 AWG
0.450 0.67
0.568 0.85
0.034 0.05
179 81.19
8.4 21.34
79 79
More Options
4 AWG 4 AWG
0.282 0.42
0.356 0.53
0.033 0.05
285 129.27
9.5 24.13
104 104
More Options
2 AWG 2 AWG
0.179 0.27
0.226 0.34
0.031 0.05
453 205.48
10.6 26.92
138 138
More Options
1 AWG 1 AWG
0.143 0.21
0.180 0.27
0.031 0.05
572 259.45
12.0 30.48
161 161
More Options
1/0 AWG 1/0 AWG
0.109 0.16
0.142 0.21
0.030 0.04
746 338.38
13.2 33.53
186 186
More Options
2/0 AWG 2/0 AWG
0.090 0.13
0.114 0.17
0.030 0.04
910 412.77
13.0 33.02
215 215
More Options
4/0 AWG 4/0 AWG
0.057 0.08
0.073 0.11
0.029 0.04
1447 656.35
16.3 41.40
287 287
More Options
250 KCMIL 250 KCMIL
0.048 0.07
0.062 0.09
0.026 0.04
1710 775.64
19.1 48.51
320 320
More Options
350 KCMIL 350 KCMIL
0.035 0.05
0.046 0.07
0.025 0.04
2394 1085.90
21.4 54.36
394 394

* Ampacities based upon ICEA S-75-381 Table H-1.
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.

Standards & References

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

Construction

  1. Conductor: Tin coated, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B33/B172
  2. Separator Tape: Non-conducting tape applied between the conductor and insulation to facilitate stripping and Ethylene Propylene Rubber (EPR), color coded black, white, red.
  3. Ground Conductors: Two mylar taped, tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172
  4. Ground Check Conductor: Tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172 with yellow, high durometer, Ethylene Propylene Rubber (EPR) insulation.
  5. Filler:Filler as needed
  6. Binder: Binder Tape
  7. Inner Jacket:Black, mold cured, extra heavy-duty integral fill flame resistant, thermosetting Chlorinated Polyethylene (CPE)
  8. Reinforcement:Reinforcing twine applied between the two jacket layers
  9. Outer Jacket:Black, mold cured, extra heavy-duty, modified integral fill, flame resistant, thermosetting Chlorinated Polyethylene (CPE). Alternate jacket colors available
  10. Reflective Stripe:Highly visible reflective stripe embedded into the outer jacket to increase safety and help prevent cable runover (optional, contact your sales representative for part number)