Southwire's USE-2 600 Volts or RHH/RHW-2 1000 Volts power cables are suited for use in wet and dry areas, conduits, ducts, troughs, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lb/ft maximum sidewall pressure.
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Approx. OD (inches) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
| More Options |
12 AWG
12 AWG
|
1
1
|
SOLID
SOLID
|
0.081
0.21
|
45
1.14
|
0.171
0.43
|
0.175
0.44
|
19
28
|
28
42
|
| More Options |
12 AWG
12 AWG
|
1
1
|
7
7
|
0.089
0.23
|
45
1.14
|
0.179
0.45
|
0.183
0.46
|
20
30
|
29
43
|
| More Options |
10 AWG
10 AWG
|
1
1
|
7
7
|
0.113
0.29
|
45
1.14
|
0.203
0.52
|
0.207
0.53
|
32
48
|
43
64
|
| More Options |
8 AWG
8 AWG
|
1
1
|
7
7
|
0.142
0.36
|
60
1.52
|
0.262
0.67
|
0.268
0.68
|
95
141
|
69
103
|
| More Options |
6 AWG
6 AWG
|
1
1
|
7
7
|
0.178
0.45
|
60
1.52
|
0.298
0.76
|
0.304
0.77
|
81
121
|
103
153
|
| More Options |
4 AWG
4 AWG
|
1
1
|
7
7
|
0.225
0.57
|
60
1.52
|
0.345
0.88
|
0.351
0.89
|
128
190
|
155
231
|
| More Options |
2 AWG
2 AWG
|
1
1
|
7
7
|
0.283
0.72
|
60
1.52
|
0.403
1.02
|
0.409
1.04
|
205
305
|
237
353
|
| More Options |
1 AWG
1 AWG
|
1
1
|
19
19
|
0.322
0.82
|
80
2.03
|
0.482
1.22
|
0.489
1.24
|
258
384
|
308
458
|
| More Options |
1/0 AWG
1/0 AWG
|
1
1
|
19
19
|
0.362
0.92
|
80
2.03
|
0.522
1.33
|
0.528
1.34
|
325
484
|
380
566
|
| More Options |
2/0 AWG
2/0 AWG
|
1
1
|
19
19
|
0.405
1.03
|
80
2.03
|
0.565
1.44
|
0.572
1.45
|
410
610
|
470
699
|
| More Options |
3/0 AWG
3/0 AWG
|
1
1
|
19
19
|
0.456
1.16
|
80
2.03
|
|
0.616
1.56
|
518
771
|
598
890
|
| More Options |
4/0 AWG
4/0 AWG
|
1
1
|
19
19
|
0.512
1.30
|
80
2.03
|
0.672
1.71
|
0.678
1.72
|
653
972
|
728
1083
|
| More Options |
250 KCMIL
250 KCMIL
|
1
1
|
37
37
|
0.558
1.42
|
95
2.41
|
0.748
1.90
|
0.742
1.88
|
771
1147
|
865
1287
|
| More Options |
300 KCMIL
300 KCMIL
|
1
1
|
37
37
|
0.611
1.55
|
95
2.41
|
0.801
2.03
|
0.794
2.02
|
926
1378
|
1026
1527
|
| More Options |
350 KCMIL
350 KCMIL
|
1
1
|
37
37
|
0.661
1.68
|
95
2.41
|
0.851
2.16
|
0.861
2.19
|
1081
1609
|
1191
1772
|
| More Options |
400 KCMIL
400 KCMIL
|
1
1
|
37
37
|
0.706
1.79
|
95
2.41
|
0.896
2.28
|
0.885
2.25
|
1235
1838
|
1349
2008
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
37
37
|
0.789
2.00
|
95
2.41
|
0.979
2.49
|
0.966
2.45
|
1544
2298
|
1670
2485
|
| More Options |
600 KCMIL
600 KCMIL
|
1
1
|
61
61
|
0.866
2.20
|
110
2.79
|
1.086
2.76
|
1.072
2.72
|
1853
2758
|
2012
2994
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
61
61
|
0.968
2.46
|
110
2.79
|
1.188
3.02
|
1.171
2.97
|
2316
3447
|
2492
3709
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
61
61
|
1.117
2.84
|
110
2.79
|
1.337
3.40
|
1.349
3.43
|
3088
4595
|
3295
4904
|
• TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
| Cond. Size | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
| More Options |
12 AWG
12 AWG
|
1
1
|
0.7
1.78
|
|
1.662
2.47
|
2.063
3.07
|
0.054
0.08
|
25
25
|
30
30
|
| More Options |
12 AWG
12 AWG
|
1
1
|
0.7
1.78
|
|
1.662
2.47
|
2.063
3.07
|
0.054
0.08
|
25
25
|
30
30
|
| More Options |
10 AWG
10 AWG
|
1
1
|
0.8
2.03
|
|
1.040
1.55
|
1.291
1.92
|
0.050
0.07
|
35
35
|
40
40
|
| More Options |
8 AWG
8 AWG
|
1
1
|
1.1
2.79
|
132
59.87
|
0.653
0.97
|
0.810
1.21
|
0.052
0.08
|
50
50
|
55
55
|
| More Options |
6 AWG
6 AWG
|
1
1
|
1.2
3.05
|
209
94.80
|
0.411
0.61
|
0.510
0.76
|
0.051
0.08
|
65
65
|
75
75
|
| More Options |
4 AWG
4 AWG
|
1
1
|
1.4
3.56
|
333
151.05
|
0.258
0.38
|
0.320
0.48
|
0.048
0.07
|
85
85
|
95
95
|
| More Options |
2 AWG
2 AWG
|
1
1
|
1.6
4.06
|
530
240.40
|
0.162
0.24
|
0.201
0.30
|
0.045
0.07
|
115
115
|
130
130
|
| More Options |
1 AWG
1 AWG
|
1
1
|
2
5.08
|
669
303.45
|
0.128
0.19
|
0.159
0.24
|
0.046
0.07
|
130
130
|
145
145
|
| More Options |
1/0 AWG
1/0 AWG
|
1
1
|
2.1
5.33
|
844
382.83
|
0.102
0.15
|
0.127
0.19
|
0.044
0.07
|
150
150
|
170
170
|
| More Options |
2/0 AWG
2/0 AWG
|
1
1
|
2.3
5.84
|
1064
482.62
|
0.082
0.12
|
0.102
0.15
|
0.043
0.06
|
175
175
|
195
195
|
| More Options |
3/0 AWG
3/0 AWG
|
1
1
|
2.5
6.35
|
1342
608.72
|
0.064
0.10
|
0.078
0.12
|
0.042
0.06
|
200
200
|
225
225
|
| More Options |
4/0 AWG
4/0 AWG
|
1
1
|
2.7
6.86
|
1692
767.48
|
0.051
0.08
|
0.063
0.09
|
0.041
0.06
|
230
230
|
260
260
|
| More Options |
250 KCMIL
250 KCMIL
|
1
1
|
3
7.62
|
2000
907.18
|
0.043
0.06
|
0.053
0.08
|
0.041
0.06
|
255
255
|
290
290
|
| More Options |
300 KCMIL
300 KCMIL
|
1
1
|
3.2
8.13
|
2400
1088.62
|
0.036
0.05
|
0.045
0.07
|
0.041
0.06
|
285
285
|
320
320
|
| More Options |
350 KCMIL
350 KCMIL
|
1
1
|
3.4
8.64
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
0.040
0.06
|
310
310
|
350
350
|
| More Options |
400 KCMIL
400 KCMIL
|
1
1
|
3.5
8.89
|
3200
1451.49
|
0.027
0.04
|
0.035
0.05
|
0.040
0.06
|
335
335
|
380
380
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
3.9
9.91
|
4000
1814.37
|
0.021
0.03
|
0.027
0.04
|
0.039
0.06
|
380
380
|
430
430
|
| More Options |
600 KCMIL
600 KCMIL
|
1
1
|
5.4
13.72
|
4800
2177.24
|
0.018
0.03
|
0.024
0.04
|
0.039
0.06
|
420
420
|
475
475
|
| More Options |
750 KCMIL
750 KCMIL
|
1
1
|
5.9
14.99
|
6000
2721.55
|
0.014
0.02
|
0.019
0.03
|
0.038
0.06
|
475
475
|
535
535
|
| More Options |
1000 KCMIL
1000 KCMIL
|
1
1
|
6.7
17.02
|
8000
3628.74
|
0.011
0.02
|
0.016
0.02
|
0.037
0.06
|
545
545
|
615
615
|
• Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
• Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.
| Size (Strand) | Black | Red | Blue | White | Brown | Orange | Yellow | Gray | Green | Purple |
|
12 (Solid)
12 (Solid)
|
|
|
|
|
|
|
|
|
|
|
|
12 (7)
12 (7)
|
|
|
|
|
|
|
|
|
|
|
|
10 (7)
10 (7)
|
|
|
|
|
|
|
|
|
||
|
8 (7)
8 (7)
|
|
|
|
|
|
|||||
|
6 (7)
6 (7)
|
646503
646503
|
646504
646504
|
646506
646506
|
646507
646507
|
|
|||||
|
4 (7)
4 (7)
|
|
588746
588746
|
|
|
||||||
|
3 (7)
3 (7)
|
113480
113480
|
|
|
|
|
|
|
|
587189
587189
|
|
|
2 (7)
2 (7)
|
620746
620746
|
616347
616347
|
616346
616346
|
620747
620747
|
|
|||||
|
1 (19)
1 (19)
|
|
|
|
647620
647620
|
647621
647621
|
647622
647622
|
|
|
|
|
|
1/0 (19)
1/0 (19)
|
|
|
643973
643973
|
|
|
|
|
|
|
|
|
2/0 (19)
2/0 (19)
|
666096
666096
|
|
|
|
|
|
|
|
||
|
3/0 (19)
3/0 (19)
|
|
|
|
|
|
|
|
|
|
|
|
4/0 (19)
4/0 (19)
|
647338
647338
|
|
|
|
|
|
|
|||
|
250 (37)
250 (37)
|
|
|
|
|
|
|
|
|
|
|
|
300 (37)
300 (37)
|
|
|
|
|
|
|
|
|
|
|
|
350 (37)
350 (37)
|
|
|
|
|
|
|
|
|
||
|
400 (37)
400 (37)
|
|
|
|
|
|
|
|
|
|
|
|
500 (37)
500 (37)
|
678974
678974
|
580165
580165
|
580166
580166
|
580168
580168
|
580169
580169
|
|
|
|||
|
600 (61)
600 (61)
|
|
|
|
139369
139369
|
139370
139370
|
139371
139371
|
|
|
|
|
|
750 (61)
750 (61)
|
|
|
|
|
|
|||||
|
1000 (61)
1000 (61)
|
|
|
|
|
|
|
|
|
|