Calculators

Instant answers to help better navigate your job site calculations.

Access Southwire’s Free Calculating Tools

To help you work most efficiently, we've created a number of calculating tools to aid in your wire and cable installations.
Re3TM Voltage Drop Calculator
Helps determine the proper wire size for an electrical circuit based on the voltage drop and current carrying capacity of an electrical circuit.
Re3TM Cable Pulling Calculator
Determinate conduit size, fill percentage, pulling tensions, cable sidewall pressure, and jam probability with the new Re3TM Cable Pull Calculator.
Configurator Plus™ Web App
Optimizes jobsite installations with faster quotes and direct wire requests.
Re3TM Conduit Fill Calculator
Conduit Fill is the percent of area inside the conduit taken up by the cable(s). Provides quick and easy results for the conduit fill percent, per NEC® guidelines.
Re3™ MCAP ® Cost Calculator
Quickly and easily illustrates the potential labor cost savings when using MCAP ® cable in place of traditional MC cable.
Lighting Calculator
See how much you can save by switching your traditional temporary lighting to LED.
Re3™ VFD Cable Selector
Select the properly sized VFD cables for your specific installation based on application temperature, drive horsepower, and operating voltage.
Re3™ Power Conversion Calculator
For AC & DC Electrical Systems in Transportation (EV, Rail, Airports), Renewable Power (Solar, Wind, BESS), Utility and Commercial Buildings.
Re3TM Concentric Neutral Calculator
Calculate your best concentric neutral configuration for Medium Voltage Cables based on ICEA S-94-649 standard for Utility and Renewable (Solar, Wind, BESS) applications.
Re3TM CIC Labor Saving Calculator
The industry’s first estimator showing the reduction of installation labor for Southwire®  Cable-in-Conduit (CIC) compared to pulling cables into PVC ducts.
Re3TM Building Wire Selector Calculator
This program determines the minimum conductor size and the best wire and cable type for a particular installation, following the National Electrical Code® wiring methods.
Re3TM Copper to Aluminum to Copper Conductor Conversion Calculator

Convert Copper to Aluminum or Aluminum to Copper by obtaining a snap view of the most important variables involved in the conversion process.

Re3TM Building Wire Reliability Index Calculator
Upgrade or upsize cables for critical infrastructure applications such as Data Centers, Healthcare Facilities, Wastewater Treatment Plants, Ports & Airports, or any heavily loaded systems.
Re3TM Lead Wire Ampacity Calculator
Compute the ampacity of appliance wires, hook‑up and lead wires for OEM equipment, Factory Automation systems, and Data Center applications under standard installation conditions, using values from the Neher–McGrath thermal analysis method and applying correction factors for ambient temperature and conductor grouping.