Suitable for use as follows:
| Conductor | Ground Wire | Neutral Wire | |||||||
| Size (AWG or kcmil) (mm2) | No. of Conductors | Stranding | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Size (AWG) | Ground Size UOM | Size (AWG) | Conductor Colors | |
| More Options |
1 AWG
1 AWG
|
3
3
|
Stranded
Stranded
|
1203
30.56
|
1352
2012
|
6
6
|
AWG
AWG
|
|
BRN, ORG, YLW, 6 GRN GND
BRN, ORG, YLW, 6 GRN GND
|
| More Options |
1 AWG
1 AWG
|
4
4
|
Stranded
Stranded
|
1423
36.14
|
1647
2451
|
6
6
|
AWG
AWG
|
1
1
|
BLK, RED, BLU, WHT, 6 GRN GND, 6 GRN-YLW GND, 0
BLK, RED, BLU, WHT, 6 GRN GND, 6 GRN-YLW GND, 0
|
| More Options |
1/0 AWG
1/0 AWG
|
4
4
|
Stranded
Stranded
|
1677
42.60
|
2378
3539
|
3
3
|
AWG
AWG
|
1/0
1/0
|
BLK/RED/BLU/WHT/3 GRN GND/3 GRN-YLW GND
BLK/RED/BLU/WHT/3 GRN GND/3 GRN-YLW GND
|
| More Options |
2/0 AWG
2/0 AWG
|
3
3
|
Stranded
Stranded
|
1447
36.76
|
1793
2668
|
6
6
|
AWG
AWG
|
|
BRN, ORG, YLW, 6 GRN GNDROUND
BRN, ORG, YLW, 6 GRN GNDROUND
|
| More Options |
3/0 AWG
3/0 AWG
|
3
3
|
Stranded
Stranded
|
1719
43.66
|
2384
3548
|
3
3
|
AWG
AWG
|
|
BRN, ORG, YLW, 3 GRN GNDROUND
BRN, ORG, YLW, 3 GRN GNDROUND
|
| More Options |
3/0 AWG
3/0 AWG
|
4
4
|
Stranded
Stranded
|
1723
43.76
|
2813
4187
|
4
4
|
AWG
AWG
|
|
BRN/ORG/YLW/GRY/4 GRN GND 0
BRN/ORG/YLW/GRY/4 GRN GND 0
|
| More Options |
4/0 AWG
4/0 AWG
|
3
3
|
Stranded
Stranded
|
1670
42.42
|
2680
3988
|
2
2
|
AWG
AWG
|
|
BRN/ORG/YLW/2 GRN GND
BRN/ORG/YLW/2 GRN GND
|
| More Options |
4/0 AWG
4/0 AWG
|
4
4
|
Stranded
Stranded
|
1797
45.64
|
3425
5097
|
2
2
|
AWG
AWG
|
4/0
4/0
|
1-BK/2-RD/3-BU/WHT/ 2 BARE GNDGND, 0
1-BK/2-RD/3-BU/WHT/ 2 BARE GNDGND, 0
|
| More Options |
4/0 AWG
4/0 AWG
|
5
5
|
Stranded
Stranded
|
1961
49.81
|
4127
6141
|
4
4
|
AWG
AWG
|
4/0
4/0
|
BLK/RED/BLU/WHT/WHT-BLK/4 GRNGND
BLK/RED/BLU/WHT/WHT-BLK/4 GRNGND
|
| More Options |
250 KCMIL
250 KCMIL
|
4
4
|
Stranded
Stranded
|
1962
49.83
|
4390
6534
|
4
4
|
AWG
AWG
|
250
250
|
TAN/PNK/PUR/GRY-WHT/4 GRN GNDGND, 0
TAN/PNK/PUR/GRY-WHT/4 GRN GNDGND, 0
|
| More Options |
250 KCMIL
250 KCMIL
|
5
5
|
Stranded
Stranded
|
2136
54.25
|
4799
7141
|
4
4
|
AWG
AWG
|
250
250
|
BLK/RED/BLU/WHT/WHT/4 GRN GND GND, 0
BLK/RED/BLU/WHT/WHT/4 GRN GND GND, 0
|
| More Options |
350 KCMIL
350 KCMIL
|
3
3
|
Stranded
Stranded
|
2081
52.86
|
4462
6640
|
3/0
3/0
|
AWG
AWG
|
|
BRN/ORG/YLW/3/0 GRN GND
BRN/ORG/YLW/3/0 GRN GND
|
| More Options |
350 KCMIL
350 KCMIL
|
4
4
|
Stranded
Stranded
|
2264
57.51
|
5606
8343
|
2/0
2/0
|
AWG
AWG
|
|
BLK/BLK/RED/RED/ 2/0 BARE GNDND, 0
BLK/BLK/RED/RED/ 2/0 BARE GNDND, 0
|
| More Options |
500 KCMIL
500 KCMIL
|
3
3
|
Stranded
Stranded
|
2451
62.26
|
6053
9007
|
1/0
1/0
|
AWG
AWG
|
|
BRN, ORG, YLW, 1/0 GRN GND
BRN, ORG, YLW, 1/0 GRN GND
|
| More Options |
600 KCMIL
600 KCMIL
|
3
3
|
Stranded
Stranded
|
2527
64.19
|
7116
10590
|
4/0
4/0
|
AWG
AWG
|
|
BRN/ORG/YLW/4/0 GRN GND
BRN/ORG/YLW/4/0 GRN GND
|
| More Options |
600 KCMIL
600 KCMIL
|
4
4
|
Stranded
Stranded
|
2716
68.99
|
8703
12951
|
2
2
|
AWG
AWG
|
600
600
|
BLK/RED/BLU/WHT/2 GRN GND 0
BLK/RED/BLU/WHT/2 GRN GND 0
|
Southwire's Armorlite® Type MC Cable - Multi-Circuit meets or exceeds the following requirements:
Southwire Copper Riser MC™ is constructed with Type THHN/THWN-2 conductors and a bare equipment grounding conductor. A binder tape is wrapped over the conductors and an integral polymeric binder jacket is applied under armor for continuous conductor support. Aluminum interlocking armor is applied snuggly over the assembly. An optional overall PVC Jacket can be applied over the armor.