SPEC: 13030

Fire Alarm FPLR Solid Non-Shielded SPEC13030

300V, 60°C, Multi-Conductor, Unshielded, Solid Copper as FPLR. Rated CMR/CL3R/FPLR CMG SUN RES FT4. Minimum Operating Temperature -10°C, Maximum Operating Temperature 60°C

Download Category Specifications
PDF Excel Table

Application & Features

Fire protective signaling circuits. Also for smoke detectors, voice communications, audio control and initiating circuits. Article 760 of the NEC. Minimum Operating Temperature -10°C, Maximum Operating Temperature 60°C

Specifications

Select more options below for part numbers, packaging, and color options:
Cable Type Cond. Size Conductor Number Cond. Type Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Jacket Thickness (mils) (mm) Approx. OD (inches) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km) Application DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Min. Bend Radius (in) (cm)
More Options
FPLR FPLR
18 AWG 18 AWG
2 2
CU CU
Solid Solid
0.040 0.10
10 0.25
15 0.38
0.200 0.51
10 15
18 27
6.669 9.92
8.030 11.95
0.8 2.03
More Options
FPLR FPLR
18 AWG 18 AWG
4 4
CU CU
Solid Solid
0.040 0.10
10 0.25
15 0.38
0.242 0.61
20 30
33 49
6.669 9.92
8.030 11.95
0.9 2.29
More Options
FPLR FPLR
16 AWG 16 AWG
2 2
CU CU
Solid Solid
0.050 0.13
10 0.25
15 0.38
0.220 0.56
16 24
26 39
4.181 6.22
5.030 7.49
0.8 2.03
More Options
FPLR FPLR
16 AWG 16 AWG
4 4
CU CU
Solid Solid
0.050 0.13
10 0.25
15 0.38
0.266 0.68
32 48
47 70
4.181 6.22
5.030 7.49
1.0 2.54
More Options
FPLR FPLR
14 AWG 14 AWG
2 2
CU CU
Solid Solid
0.064 0.16
10 0.25
15 0.38
0.248 0.63
25 37
38 57
2.631 3.92
3.170 4.72
0.9 2.29
More Options
FPLR FPLR
14 AWG 14 AWG
4 4
CU CU
Solid Solid
0.064 0.16
10 0.25
15 0.38
0.300 0.76
51 76
69 103
2.631 3.92
3.170 4.72
1.2 3.05
More Options
FPLR FPLR
12 AWG 12 AWG
2 2
CU CU
Solid Solid
0.080 0.20
10 0.25
15 0.38
0.280 0.71
40 60
55 82
Fire Alarm Fire Alarm
1.662 2.47
2.000 2.98
1.1 2.79

Standards & References

  • UL 1424 Cables for Power-Limited Fire-Alarm Circuits
  • ASTM B3 Soft or Annealed Copper Wire
  • UL1424 Listed FPLR
  • NFPA 70, NFPA 101, and NFPA 502
  • UL 13 Power-Limited Circuit Cables
  • UL 444 Communications Cables (22 AWG - 16 AWG)
  • RoHS-2 (European Directive 2011/65/EU)

Construction

  1. Conductor:Solid bare copper per ASTM B3
  2. Insulation:Low Smoke Polyvinyl Chloride (LS-PVC)
  3. Rip Cord:Rip cord for ease of jacket removal
  4. Jacket:Red Low Smoke Polyvinyl Chloride (LS-PVC)

Resources

There are no downloadable resources for this product.