CU FRXLPE PVC CONTROL CABLE

Control Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

Download Category Specifications
PDF Excel Table

Application

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Only UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Specifications

Select a set of products below for more information:
Conductor
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
3 3
14 AWG 14 AWG
7 7
30 0.76
390 9.91
96 143
More Options
4 4
14 AWG 14 AWG
7 7
30 0.76
424 10.77
113 168
More Options
12 12
14 AWG 14 AWG
7 7
30 0.76
692 17.58
307 457
More Options
19 19
14 AWG 14 AWG
7 7
30 0.76
805 20.46
455 678
More Options
3 3
12 AWG 12 AWG
7 7
30 0.76
428 10.89
122 182
More Options
4 4
12 AWG 12 AWG
7 7
30 0.76
467 11.88
153 228
More Options
2 2
10 AWG 10 AWG
7 7
30 0.76
452 11.49
125 186
More Options
4 4
10 AWG 10 AWG
7 7
30 0.76
557 14.16
229 340
More Options
5 5
10 AWG 10 AWG
7 7
30 0.76
591 15.02
282 420
More Options
7 7
10 AWG 10 AWG
7 7
30 0.76
657 16.69
365 543
More Options
9 9
10 AWG 10 AWG
7 7
30 0.76
765 19.44
507 754
More Options
12 12
10 AWG 10 AWG
7 7
30 0.76
908 23.08
634 944
More Options
19 19
10 AWG 10 AWG
7 7
30 0.76
1043 26.49
999 1487
More Options
3 3
2 AWG 2 AWG
7 7
45 1.14
973 24.73
882 1313

Standards & References

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • VW-1 (Vertical-Wire) Flame Test

Construction

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Rip Chord:Rip chord for ease of jacket removal
  6. Overall Jacket:Polyvinyl Chloride (PVC) Jacket