SPEC: 70250

600V STOOW Cord with Jacket 105°C. Silicone Free SPEC70250

600 Volt, 105°C Flexible Cord. Heat and Moisture PVC Insulation and Sunlight, Heat, Moisture, Oil Resistant, and Flexible PVC Jacket. Rated for Extra Hard-Usage Service Cords. Approved for Outdoor use. Rated UL VW-1 and CSA FT1, FT2 Flame Resistant.

Download Category Specifications
PDF Excel Table

Application & Features

Southwire Type STOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2020 National Electric Code. Some typical applications for Type STOOW include, but are not limited to: Washing Machines and other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites.

Specifications

Select more options below for part numbers, packaging, and color options:
Conductor
Size (AWG or kcmil) (mm2) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Conductor Colors
More Options
16 AWG 16 AWG
3 3
26 26
410 10.41
89 132
BLACK/WHITE/RED BLACK/WHITE/RED
More Options
16 AWG 16 AWG
3 3
65 65
407 10.34
93 138
BLACK/WHITE/GREEN-YELLOW BLACK/WHITE/GREEN-YELLOW
More Options
16 AWG 16 AWG
4 4
26 26
415 10.54
105 156
BLACK/WHITE/GREEN/RED BLACK/WHITE/GREEN/RED
More Options
16 AWG 16 AWG
5 5
65 65
500 12.70
143 213
BLACK/WHITE/RED/ORANGE/GREEN-YELLOW BLACK/WHITE/RED/ORANGE/GREEN-YELLOW
More Options
16 AWG 16 AWG
6 6
65 65
535 13.59
170 253
BLACK/WHITE/RED/GREEN-YELLOW/ORANGE/BLUE BLACK/WHITE/RED/GREEN-YELLOW/ORANGE/BLUE
More Options
16 AWG 16 AWG
8 8
65 65
575 14.61
201 300
More Options
16 AWG 16 AWG
10 10
65 65
659 16.74
232 346
More Options
16 AWG 16 AWG
12 12
65 65
690 17.53
279 416
More Options
14 AWG 14 AWG
3 3
41 41
530 13.46
155 231
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
12 AWG 12 AWG
3 3
65 65
605 15.37
210 313
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
12 AWG 12 AWG
4 4
65 65
665 16.89
246 366
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN

* Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
** Tinned Copper

Stock Number Conductor Size Conductor Number Filler Binder Insulation Colors Jacket Color
652927
16 16
3 3
None None
White Tissue Paper White Tissue Paper
Black, White, Green-Yellow Black, White, Green-Yellow
Black Black
589056
16 16
3 3
None None
White Tissue Paper White Tissue Paper
Black, White, Green-Yellow Black, White, Green-Yellow
Yellow Yellow
207400
16 16
3 3
Polypropylene Polypropylene
None None
Black, White, Red Black, White, Red
Black Black
672344
16 16
3 3
Polypropylene Polypropylene
None None
Black, White, Green Black, White, Green
Black Black
560733
16 16
4 4
Paper Paper
White Tissue Paper White Tissue Paper
Black, White, Green, Red Black, White, Green, Red
Yellow Yellow
587622
16 16
5 5
Polypropylene Polypropylene
White Tissue Paper White Tissue Paper
Black, White, Red, Orange, Green-Yellow Black, White, Red, Orange, Green-Yellow
Yellow Yellow
588983
16 16
6 6
Polypropylene Polypropylene
White Tissue Paper White Tissue Paper
Black, White, Red, Green-Yellow, Orange, Blue Black, White, Red, Green-Yellow, Orange, Blue
Yellow Yellow
578058
16 16
8 8
Polypropylene Polypropylene
White Tissue Paper White Tissue Paper
Black, White, Brown, Pink, Blue, Yellow, Orange, Red Black, White, Brown, Pink, Blue, Yellow, Orange, Red
Yellow Yellow
588986
16 16
8 8
PVC PVC
White Tissue Paper White Tissue Paper
Black, White, Red, Green-Yellow, Orange, Blue, White-Black, Red-Black Black, White, Red, Green-Yellow, Orange, Blue, White-Black, Red-Black
Yellow Yellow
201930
16 16
10 10
Polypropylene Polypropylene
Mylar Mylar
Black, White, Green-Yellow, Red, Orange-Black, Green-Black, Red-Black, White-Black, Blue, Orange Black, White, Green-Yellow, Red, Orange-Black, Green-Black, Red-Black, White-Black, Blue, Orange
Yellow Yellow
201940
16 16
12 12
Polypropylene Polypropylene
Mylar Mylar
Black, White, Red, Green-Yellow, Black-White, Blue-Black, Orange-Black, Green-Black, Red-Black, White-Black, Blue, Orange Black, White, Red, Green-Yellow, Black-White, Blue-Black, Orange-Black, Green-Black, Red-Black, White-Black, Blue, Orange
Yellow Yellow
263290 263290
14 14
3 3
Polypropylene Polypropylene
None None
Black, White, Green-Yellow Black, White, Green-Yellow
Black Black
672538
14 14
3 3
Polypropylene Polypropylene
None None
Black, White, Green Black, White, Green
Black Black
560703
14 14
3 3
None None
White Tissue Paper White Tissue Paper
Black, White, Green Black, White, Green
Yellow Yellow
593628
14 14
3 3
None None
White Tissue Paper White Tissue Paper
Black, Green, Red Black, Green, Red
Yellow Yellow
578584
14 14
3 3
None None
White Tissue Paper White Tissue Paper
Black, White, Green Black, White, Green
Yellow Yellow
672540
12 12
3 3
Polypropylene Polypropylene
None None
Black, White, Green Black, White, Green
Black Black
560708
12 12
3 3
None None
White Tissue Paper White Tissue Paper
Black, White, Green Black, White, Green
Yellow Yellow
564743
12 12
4 4
Paper Paper
White Tissue Paper White Tissue Paper
Black, White, Red, Green Black, White, Red, Green
Black Black
677522 677522
10 10
3 3
Polypropylene Polypropylene
White Tissue Paper White Tissue Paper
Black, Red, Green Black, Red, Green
Black Black
606210 606210
10 10
4 4
Polypropylene Polypropylene
Mylar Mylar
Black, Black, Green-Yellow, Black Black, Black, Green-Yellow, Black
Gray Gray

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B174 Standard Specification for Bunch-Stranded Copper
  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • RoHS-3 Complies with European Directive 2015/863

Construction

  1. Conductor:Class K stranded bare or tinned copper per ASTM B3 and B174 B33
  2. Insulation:Heat, moisture, and oil resistant resistant PVC (see Table 3 for insulation colors)
  3. Filler and Binder:Fillers as needed to make core round and binder as needed to keep core assembly round on certain constructions (see Table 3 for details)
  4. Jacket:Sunlight, heat, moisture, and oil resistant PVC (see Table 3 for jacket color)