For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs./FT maximum sidewall pressure.
| Cond. Size | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Ground Size | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (inches) (cm) | Approx. Weight (lbs/1000') (kgs/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | |
| More Options |
8 AWG
8 AWG
|
7
7
|
0.141
0.36
|
45
1.14
|
1x10
1x10
|
65
1.65
|
0.809
2.05
|
45
1.14
|
0.899
2.28
|
399
594
|
264
119.75
|
6.2
15.75
|
| More Options |
8 AWG
8 AWG
|
7
7
|
0.141
0.36
|
45
1.14
|
1x10
1x10
|
65
1.65
|
0.846
2.15
|
45
1.14
|
0.936
2.38
|
475
707
|
396
179.62
|
6.5
16.51
|
| More Options |
8 AWG
8 AWG
|
7
7
|
0.141
0.36
|
45
1.14
|
1x10
1x10
|
65
1.65
|
0.905
2.30
|
55
1.40
|
1.015
2.58
|
578
860
|
528
239.50
|
7.1
18.03
|
| More Options |
6 AWG
6 AWG
|
7
7
|
0.177
0.45
|
60
1.52
|
1x8
1x8
|
65
1.65
|
0.941
2.39
|
45
1.14
|
1.031
2.62
|
540
804
|
419
190.06
|
7.2
18.29
|
| More Options |
6 AWG
6 AWG
|
7
7
|
0.177
0.45
|
60
1.52
|
1x8
1x8
|
65
1.65
|
1.099
2.79
|
45
1.14
|
1.189
3.02
|
714
1063
|
629
285.31
|
8.3
21.08
|
| More Options |
6 AWG
6 AWG
|
7
7
|
0.177
0.45
|
60
1.52
|
1x8
1x8
|
85
2.16
|
1.216
3.09
|
45
1.14
|
1.306
3.32
|
889
1323
|
839
380.56
|
9.1
23.11
|
| More Options |
4 AWG
4 AWG
|
7
7
|
0.225
0.57
|
60
1.52
|
1x8
1x8
|
85
2.16
|
1.144
2.91
|
55
1.40
|
1.254
3.19
|
759
1130
|
667
302.55
|
8.7
22.10
|
| More Options |
4 AWG
4 AWG
|
7
7
|
0.225
0.57
|
60
1.52
|
1x8
1x8
|
85
2.16
|
1.242
3.15
|
45
1.14
|
1.332
3.38
|
958
1426
|
1001
454.05
|
9.3
23.62
|
| More Options |
4 AWG
4 AWG
|
7
7
|
0.225
0.57
|
60
1.52
|
1x8
1x8
|
85
2.16
|
1.330
3.38
|
45
1.14
|
1.420
3.61
|
1150
1711
|
1335
605.55
|
9.9
25.15
|
| More Options |
2 AWG
2 AWG
|
7
7
|
0.282
0.72
|
60
1.52
|
1x6
1x6
|
85
2.16
|
1.298
3.30
|
55
1.40
|
1.408
3.58
|
1050
1563
|
1061
481.26
|
9.8
24.89
|
| More Options |
2 AWG
2 AWG
|
7
7
|
0.282
0.72
|
60
1.52
|
1x6
1x6
|
85
2.16
|
1.363
3.46
|
45
1.14
|
1.453
3.69
|
1286
1914
|
1592
722.12
|
10.1
25.65
|
| More Options |
2 AWG
2 AWG
|
7
7
|
0.282
0.72
|
60
1.52
|
1x6
1x6
|
85
2.16
|
1.465
3.72
|
45
1.14
|
1.555
3.95
|
1561
2323
|
2123
962.98
|
10.8
27.43
|
| More Options |
1 AWG
1 AWG
|
19
19
|
0.322
0.82
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.548
3.93
|
55
1.40
|
1.658
4.21
|
1604
2387
|
2008
910.81
|
11.6
29.46
|
| More Options |
1 AWG
1 AWG
|
19
19
|
0.322
0.82
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.672
4.25
|
55
1.40
|
1.782
4.53
|
1981
2948
|
2678
1214.72
|
12.4
31.50
|
| More Options |
1/0 AWG
1/0 AWG
|
19
19
|
0.361
0.92
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.632
4.15
|
55
1.40
|
1.742
4.42
|
1859
2766
|
2534
1149.40
|
12.1
30.73
|
| More Options |
1/0 AWG
1/0 AWG
|
19
19
|
0.361
0.92
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.766
4.49
|
55
1.40
|
1.876
4.77
|
2315
3445
|
3379
1532.69
|
13.1
33.27
|
| More Options |
2/0 AWG
2/0 AWG
|
19
19
|
0.405
1.03
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.727
4.39
|
55
1.40
|
1.837
4.67
|
2191
3261
|
3194
1448.77
|
12.8
32.51
|
| More Options |
2/0 AWG
2/0 AWG
|
19
19
|
0.405
1.03
|
80
2.03
|
1x6
1x6
|
85
2.16
|
1.885
4.79
|
55
1.40
|
1.995
5.07
|
2787
4148
|
4259
1931.85
|
13.9
35.31
|
| More Options |
3/0 AWG
3/0 AWG
|
19
19
|
0.456
1.16
|
80
2.03
|
1x4
1x4
|
85
2.16
|
1.738
4.41
|
65
1.65
|
1.870
4.75
|
2042
3039
|
2684
1217.44
|
13.0
33.02
|
| More Options |
3/0 AWG
3/0 AWG
|
19
19
|
0.456
1.16
|
80
2.03
|
1x4
1x4
|
85
2.16
|
1.814
4.61
|
55
1.40
|
1.924
4.89
|
2621
3900
|
4027
1826.61
|
13.4
34.04
|
| More Options |
3/0 AWG
3/0 AWG
|
19
19
|
0.456
1.16
|
80
2.03
|
1x4
1x4
|
115
2.92
|
1.989
5.05
|
55
1.40
|
2.099
5.33
|
3342
4973
|
5369
2435.34
|
14.6
37.08
|
| More Options |
4/0 AWG
4/0 AWG
|
19
19
|
0.512
1.30
|
80
2.03
|
1x4
1x4
|
85
2.16
|
1.943
4.94
|
65
1.65
|
2.075
5.27
|
3205
4770
|
5078
2303.34
|
14.5
36.83
|
| More Options |
4/0 AWG
4/0 AWG
|
19
19
|
0.512
1.30
|
80
2.03
|
1x4
1x4
|
115
2.92
|
2.175
5.52
|
65
1.65
|
2.307
5.86
|
4149
6174
|
6771
3071.27
|
16.1
40.89
|
| More Options |
250 KCMIL
250 KCMIL
|
37
37
|
0.558
1.42
|
90
2.29
|
1x4
1x4
|
115
2.92
|
2.146
5.45
|
55
1.40
|
2.256
5.73
|
3761
5597
|
6000
2721.55
|
15.7
39.88
|
| More Options |
250 KCMIL
250 KCMIL
|
37
37
|
0.558
1.42
|
90
2.29
|
1x4
1x4
|
115
2.92
|
2.332
5.92
|
65
1.65
|
2.464
6.26
|
4773
7103
|
8000
3628.74
|
17.2
43.69
|
| More Options |
300 KCMIL
300 KCMIL
|
37
37
|
0.610
1.55
|
90
2.29
|
1x4
1x4
|
115
2.92
|
2.295
5.83
|
65
1.65
|
2.427
6.16
|
4388
6530
|
7200
3265.86
|
16.9
42.93
|
| More Options |
300 KCMIL
300 KCMIL
|
37
37
|
0.610
1.55
|
90
2.29
|
1x4
1x4
|
115
2.92
|
2.498
6.34
|
65
1.65
|
2.630
6.68
|
5527
8225
|
9600
4354.48
|
18.4
46.74
|
| More Options |
350 KCMIL
350 KCMIL
|
37
37
|
0.661
1.68
|
90
2.29
|
1x3
1x3
|
115
2.92
|
2.360
5.99
|
65
1.65
|
2.492
6.33
|
4939
7350
|
8400
3810.17
|
17.4
44.20
|
| More Options |
350 KCMIL
350 KCMIL
|
37
37
|
0.661
1.68
|
90
2.29
|
1x3
1x3
|
115
2.92
|
2.571
6.53
|
65
1.65
|
2.703
6.87
|
6242
9289
|
11200
5080.23
|
18.9
48.01
|
| More Options |
500 KCMIL
500 KCMIL
|
37
37
|
0.789
2.00
|
90
2.29
|
1x3
1x3
|
115
2.92
|
2.630
6.68
|
65
1.65
|
2.762
7.02
|
6545
9740
|
12000
5443.10
|
19.3
49.02
|
| More Options |
500 KCMIL
500 KCMIL
|
37
37
|
0.789
2.00
|
90
2.29
|
1x3
1x3
|
115
2.92
|
2.872
7.29
|
65
1.65
|
3.004
7.63
|
8351
12428
|
16000
7257.47
|
21.0
53.34
|
| More Options |
600 KCMIL
600 KCMIL
|
61
61
|
0.865
2.20
|
90
2.29
|
1x2
1x2
|
115
2.92
|
2.846
7.23
|
80
2.03
|
3.012
7.65
|
7779
11576
|
14400
6531.72
|
21.0
53.34
|
| More Options |
750 KCMIL
750 KCMIL
|
61
61
|
0.968
2.46
|
90
2.29
|
1x2
1x2
|
115
2.92
|
3.115
7.91
|
80
2.03
|
3.283
8.34
|
9512
14155
|
18000
8164.66
|
22.9
58.17
|
| More Options |
750 KCMIL
750 KCMIL
|
61
61
|
0.968
2.46
|
90
2.29
|
1x2
1x2
|
145
3.68
|
3.423
8.69
|
80
2.03
|
3.591
9.12
|
12223
18190
|
24000
10886.21
|
25.1
63.75
|
| More Options |
1000 KCMIL
1000 KCMIL
|
61
61
|
1.117
2.84
|
90
2.29
|
1x1
1x1
|
145
3.68
|
3.451
8.77
|
80
2.03
|
3.619
9.19
|
12221
18187
|
24000
10886.21
|
25.3
64.26
|
^ Colour Code: 2/C black, Red
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
| Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | |
| More Options |
8 AWG
8 AWG
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
| More Options |
8 AWG
8 AWG
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
| More Options |
8 AWG
8 AWG
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
| More Options |
6 AWG
6 AWG
|
0.411
0.61
|
0.495
0.74
|
0.051
0.08
|
| More Options |
6 AWG
6 AWG
|
0.411
0.61
|
0.495
0.74
|
0.051
0.08
|
| More Options |
6 AWG
6 AWG
|
0.411
0.61
|
0.495
0.74
|
0.051
0.08
|
| More Options |
4 AWG
4 AWG
|
0.258
0.38
|
0.310
0.46
|
0.048
0.07
|
| More Options |
4 AWG
4 AWG
|
0.258
0.38
|
0.310
0.46
|
0.048
0.07
|
| More Options |
4 AWG
4 AWG
|
0.258
0.38
|
0.310
0.46
|
0.048
0.07
|
| More Options |
2 AWG
2 AWG
|
0.162
0.24
|
0.195
0.29
|
0.045
0.07
|
| More Options |
2 AWG
2 AWG
|
0.162
0.24
|
0.195
0.29
|
0.045
0.07
|
| More Options |
2 AWG
2 AWG
|
0.162
0.24
|
0.195
0.29
|
0.045
0.07
|
| More Options |
1 AWG
1 AWG
|
0.128
0.19
|
0.154
0.23
|
0.046
0.07
|
| More Options |
1 AWG
1 AWG
|
0.128
0.19
|
0.154
0.23
|
0.046
0.07
|
| More Options |
1/0 AWG
1/0 AWG
|
0.102
0.15
|
0.122
0.18
|
0.044
0.07
|
| More Options |
1/0 AWG
1/0 AWG
|
0.102
0.15
|
0.122
0.18
|
0.044
0.07
|
| More Options |
2/0 AWG
2/0 AWG
|
0.081
0.12
|
0.097
0.14
|
0.043
0.06
|
| More Options |
2/0 AWG
2/0 AWG
|
0.081
0.12
|
0.097
0.14
|
0.043
0.06
|
| More Options |
3/0 AWG
3/0 AWG
|
0.064
0.10
|
0.078
0.12
|
0.042
0.06
|
| More Options |
3/0 AWG
3/0 AWG
|
0.064
0.10
|
0.078
0.12
|
0.042
0.06
|
| More Options |
3/0 AWG
3/0 AWG
|
0.064
0.10
|
0.078
0.12
|
0.042
0.06
|
| More Options |
4/0 AWG
4/0 AWG
|
0.051
0.08
|
0.062
0.09
|
0.041
0.06
|
| More Options |
4/0 AWG
4/0 AWG
|
0.051
0.08
|
0.062
0.09
|
0.041
0.06
|
| More Options |
250 KCMIL
250 KCMIL
|
0.043
0.06
|
0.053
0.08
|
0.041
0.06
|
| More Options |
250 KCMIL
250 KCMIL
|
0.043
0.06
|
0.053
0.08
|
0.041
0.06
|
| More Options |
300 KCMIL
300 KCMIL
|
0.036
0.05
|
0.045
0.07
|
0.041
0.06
|
| More Options |
300 KCMIL
300 KCMIL
|
0.036
0.05
|
0.045
0.07
|
0.041
0.06
|
| More Options |
350 KCMIL
350 KCMIL
|
0.031
0.05
|
0.039
0.06
|
0.040
0.06
|
| More Options |
350 KCMIL
350 KCMIL
|
0.031
0.05
|
0.039
0.06
|
0.040
0.06
|
| More Options |
500 KCMIL
500 KCMIL
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
| More Options |
500 KCMIL
500 KCMIL
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
| More Options |
600 KCMIL
600 KCMIL
|
0.018
0.03
|
0.025
0.04
|
0.039
0.06
|
| More Options |
750 KCMIL
750 KCMIL
|
0.014
0.02
|
0.022
0.03
|
0.038
0.06
|
| More Options |
750 KCMIL
750 KCMIL
|
0.014
0.02
|
0.022
0.03
|
0.038
0.06
|
| More Options |
1000 KCMIL
1000 KCMIL
|
0.011
0.02
|
0.018
0.03
|
0.037
0.06
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.