SPEC: 13093

Flat Speaker Wire CL3 SPEC13093

300V, 75°C, Flat Speaker Wire CL3

Download Category Specifications
PDF Excel Table

Application & Features

Southwire stranded clear speaker, polarized for use in internal audio wiring

  • Flame Test: UL 1666
  • Cable Type: CL3R, Also, CMR where UL permits (Sizes 16 AWG and smaller)
  • Voltage: 300 Volts
  • Temperature: 75ºC
  • Specifications

    Select more options below for part numbers, packaging, and color options:
    Cable Type Cond. Size Conductor Number Cond. Type Cond. Strands Diameter Over Conductor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km) Shield Type DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km)
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    22 AWG 22 AWG
    2 2
    CU CU
    7 7
    0.029 0.07
    20 0.51
    0.073 x 0.156 0.19 x 0.40
    4 6
    8 12
    None None
    16.720 24.88
    20.150 29.99
    0.030 0.04
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    18 AWG 18 AWG
    2 2
    CU CU
    16 16
    0.044 0.11
    20 0.51
    0.090 x 0.200 0.23 x 0.51
    9 13
    15 22
    None None
    7.148 10.64
    8.613 12.82
    0.036 0.05
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    16 AWG 16 AWG
    2 2
    CU CU
    26 26
    0.059 0.15
    20 0.51
    0.105 x 0.230 0.27 x 0.58
    16 24
    22 33
    None None
    4.487 6.68
    5.406 8.05
    0.033 0.05
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    16 AWG 16 AWG
    2 2
    CU CU
    65 65
    0.059 0.15
    30 0.76
    0.126 x 0.266 0.32 x 0.68
    16 24
    26 39
    None None
    4.487 6.68
    5.406 8.05
    0.033 0.05
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    14 AWG 14 AWG
    2 2
    CU CU
    41 41
    0.073 0.19
    40 1.02
    0.132 x 0.228 0.34 x 0.58
    26 39
    37 55
    None None
    2.814 4.19
    3.391 5.05
    0.058 0.09
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    14 AWG 14 AWG
    2 2
    CU CU
    105 105
    0.073 0.19
    40 1.02
    0.157 x 0.360 0.40 x 0.91
    26 39
    42 63
    None None
    2.814 4.19
    3.391 5.05
    0.058 0.09
    More Options
    Speaker Wire CL3 Speaker Wire CL3
    12 AWG 12 AWG
    2 2
    CU CU
    168 168
    0.094 0.24
    45 1.14
    0.193 x 0.410 0.49 x 1.04
    41 61
    66 98
    None None
    1.774 2.64
    2.137 3.18
    0.054 0.08

    Standards & References

    • ASTM B8 Concentric-Lay-Stranded Copper Conductors
    • UL 13 Power-Limited Circuit Cables
    • UL 444 Communications Cables (90ºC, 300V)

    Construction

    1. Conductor:One bare copper and One Tinned copper. Class K stranding sizes 18 and 16 AWG. Class M stranding sizes 14 and 12 AWG
    2. Insulation:Clear Polyvinyl Chloride PVC

    Resources