Southwire Type SEOOW Flexible Cords are permitted for Indoor and outdoor temporary power uses, portable industrial machinery and compressors, food processing and washdown facilities. Type SEOOW Cords are suitable for use in temperatures between -50°C to maximum 105°C.
| Conductor | ||||||||
| Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
| More Options |
18 AWG
18 AWG
|
6
6
|
16
16
|
484
12.29
|
118
175
|
5.5
5.5
|
6.4
6.4
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
| More Options |
18 AWG
18 AWG
|
7
7
|
16
16
|
488
12.40
|
125
186
|
4.5
4.5
|
6.4
6.4
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
| More Options |
18 AWG
18 AWG
|
8
8
|
16
16
|
517
13.13
|
141
210
|
4.5
4.5
|
6.4
6.4
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
| More Options |
18 AWG
18 AWG
|
10
10
|
16
16
|
592
15.04
|
175
261
|
3.5
3.5
|
6.4
6.4
|
|
| More Options |
18 AWG
18 AWG
|
12
12
|
16
16
|
613
15.58
|
194
289
|
3.5
3.5
|
6.4
6.4
|
|
| More Options |
18 AWG
18 AWG
|
14
14
|
16
16
|
640
16.26
|
214
319
|
3.5
3.5
|
6.4
6.4
|
|
| More Options |
18 AWG
18 AWG
|
16
16
|
16
16
|
697
17.70
|
261
388
|
3.5
3.5
|
6.4
6.4
|
|
| More Options |
16 AWG
16 AWG
|
4
4
|
26
26
|
422
10.72
|
95
142
|
10
10
|
4.12
4.12
|
BLACK/WHITE/GREEN/RED
BLACK/WHITE/GREEN/RED
|
| More Options |
16 AWG
16 AWG
|
5
5
|
26
26
|
502
12.75
|
134
200
|
8
8
|
4.12
4.12
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
| More Options |
16 AWG
16 AWG
|
6
6
|
26
26
|
533
13.54
|
151
224
|
8
8
|
4.12
4.12
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
| More Options |
16 AWG
16 AWG
|
7
7
|
26
26
|
525
13.34
|
158
235
|
7
7
|
4.12
4.12
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
| More Options |
16 AWG
16 AWG
|
8
8
|
26
26
|
560
14.22
|
179
267
|
7
7
|
4.12
4.12
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
| More Options |
16 AWG
16 AWG
|
14
14
|
26
26
|
725
18.42
|
292
435
|
5
5
|
4.12
4.12
|
|
| More Options |
16 AWG
16 AWG
|
16
16
|
26
26
|
757
19.23
|
317
472
|
5
5
|
4.12
4.12
|
|
| More Options |
14 AWG
14 AWG
|
2
2
|
41
41
|
507
12.88
|
118
175
|
18
18
|
2.64
2.64
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
14 AWG
14 AWG
|
3
3
|
41
41
|
526
13.36
|
142
211
|
18
18
|
2.64
2.64
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
14 AWG
14 AWG
|
4
4
|
41
41
|
592
15.04
|
182
270
|
15
15
|
2.64
2.64
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
| More Options |
14 AWG
14 AWG
|
6
6
|
41
41
|
690
17.53
|
248
369
|
12
12
|
2.64
2.64
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
| More Options |
14 AWG
14 AWG
|
7
7
|
41
41
|
690
17.53
|
267
397
|
10
10
|
2.64
2.64
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
| More Options |
14 AWG
14 AWG
|
8
8
|
41
41
|
743
18.87
|
304
452
|
10
10
|
2.64
2.64
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
| More Options |
14 AWG
14 AWG
|
10
10
|
41
41
|
835
21.21
|
363
540
|
7
7
|
2.64
2.64
|
|
| More Options |
12 AWG
12 AWG
|
2
2
|
65
65
|
577
14.66
|
164
244
|
25
25
|
1.66
1.66
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
12 AWG
12 AWG
|
3
3
|
65
65
|
603
15.32
|
192
285
|
25
25
|
1.66
1.66
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
12 AWG
12 AWG
|
6
6
|
65
65
|
745
18.92
|
317
471
|
16
16
|
1.66
1.66
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|