600V SEOPRENE® SEOOW Cord Control with Black Jacket 105°C PCORD22

600 Volt Cord. 105°C Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant

Download Category Specifications
Excel Table

Application & Features

Southwire Type SEOOW Flexible Cords are permitted for Indoor and outdoor temporary power uses, portable industrial machinery and compressors, food processing and washdown facilities. Type SEOOW Cords are suitable for use in temperatures between -50°C to maximum 105°C.

Specifications

Select more options below for part numbers, packaging, and color options:
Conductor
Size (AWG or kcmil) (mm2) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
More Options
18 AWG 18 AWG
6 6
16 16
484 12.29
118 175
5.5 5.5
6.4 6.4
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
18 AWG 18 AWG
7 7
16 16
488 12.40
125 186
4.5 4.5
6.4 6.4
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
18 AWG 18 AWG
8 8
16 16
517 13.13
141 210
4.5 4.5
6.4 6.4
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
18 AWG 18 AWG
10 10
16 16
592 15.04
175 261
3.5 3.5
6.4 6.4
More Options
18 AWG 18 AWG
12 12
16 16
613 15.58
194 289
3.5 3.5
6.4 6.4
More Options
18 AWG 18 AWG
14 14
16 16
640 16.26
214 319
3.5 3.5
6.4 6.4
More Options
18 AWG 18 AWG
16 16
16 16
697 17.70
261 388
3.5 3.5
6.4 6.4
More Options
16 AWG 16 AWG
4 4
26 26
422 10.72
95 142
10 10
4.12 4.12
BLACK/WHITE/GREEN/RED BLACK/WHITE/GREEN/RED
More Options
16 AWG 16 AWG
5 5
26 26
502 12.75
134 200
8 8
4.12 4.12
BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
More Options
16 AWG 16 AWG
6 6
26 26
533 13.54
151 224
8 8
4.12 4.12
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
16 AWG 16 AWG
7 7
26 26
525 13.34
158 235
7 7
4.12 4.12
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
16 AWG 16 AWG
8 8
26 26
560 14.22
179 267
7 7
4.12 4.12
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
16 AWG 16 AWG
14 14
26 26
725 18.42
292 435
5 5
4.12 4.12
More Options
16 AWG 16 AWG
16 16
26 26
757 19.23
317 472
5 5
4.12 4.12
More Options
14 AWG 14 AWG
2 2
41 41
507 12.88
118 175
18 18
2.64 2.64
BLACK/WHITE BLACK/WHITE
More Options
14 AWG 14 AWG
3 3
41 41
526 13.36
142 211
18 18
2.64 2.64
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
14 AWG 14 AWG
4 4
41 41
592 15.04
182 270
15 15
2.64 2.64
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
More Options
14 AWG 14 AWG
6 6
41 41
690 17.53
248 369
12 12
2.64 2.64
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
14 AWG 14 AWG
7 7
41 41
690 17.53
267 397
10 10
2.64 2.64
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
14 AWG 14 AWG
8 8
41 41
743 18.87
304 452
10 10
2.64 2.64
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
14 AWG 14 AWG
10 10
41 41
835 21.21
363 540
7 7
2.64 2.64
More Options
12 AWG 12 AWG
2 2
65 65
577 14.66
164 244
25 25
1.66 1.66
BLACK/WHITE BLACK/WHITE
More Options
12 AWG 12 AWG
3 3
65 65
603 15.32
192 285
25 25
1.66 1.66
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
12 AWG 12 AWG
6 6
65 65
745 18.92
317 471
16 16
1.66 1.66
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE

Standards & References

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-2 (European Directive 2011/65/EU)
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2

Construction

  1. Conductor: Class K stranded bare copper per ASTM B-174
  2. Insulation: Heat, moisture and oil resistant TPE
  3. Filler: Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket: Black TPE (other colors available upon request)