ACSR ALBARE6

Aluminum Conductor. Steel Reinforced . Bare.

Download Category Specifications
PDF Excel Table

Application & Features

ACSR-Aluminum Conductor, Steel Reinforced

Specifications

Select a set of products below for more information:
Codeword Size (AWG or kcmil) (mm2) No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
TURKEY TURKEY
6 AWG 6 AWG
6 6
198 5.04
36 54
More Options
SWAN SWAN
4 AWG 4 AWG
6 6
250 6.36
57 85
More Options
SPARROW SPARROW
2 AWG 2 AWG
6 6
315 8.02
91 136
More Options
ROBIN ROBIN
1 AWG 1 AWG
6 6
354 9.00
115 171
More Options
RAVEN RAVEN
1/0 AWG 1/0 AWG
6 6
398 10.11
145 216
More Options
QUAIL QUAIL
2/0 AWG 2/0 AWG
6 6
446 11.35
183 272
More Options
PIGEON PIGEON
3/0 AWG 3/0 AWG
6 6
501 12.74
230 343
More Options
PENGUIN PENGUIN
4/0 AWG 4/0 AWG
6 6
563 14.31
291 433
More Options
MAGPIE MAGPIE
20.87 KCMIL 20.87 KCMIL
3 3
250 6.36
38 56
More Options
GROUSE GROUSE
80 KCMIL 80 KCMIL
8 8
367 9.32
149 222
More Options
MINORCA MINORCA
110.8 KCMIL 110.8 KCMIL
12 12
480 12.20
276 411
More Options
GUINEA GUINEA
159 KCMIL 159 KCMIL
12 12
575 14.62
396 590
More Options
DORKING DORKING
190.8 KCMIL 190.8 KCMIL
12 12
628 15.95
472 702
More Options
WAXWING WAXWING
266.8 KCMIL 266.8 KCMIL
18 18
608 15.46
289 430
More Options
OSTRICH OSTRICH
300 KCMIL 300 KCMIL
26 26
680 17.27
412 613
More Options
MERLIN MERLIN
336.4 KCMIL 336.4 KCMIL
18 18
683 17.36
365 543
More Options
CHICKADEE CHICKADEE
397.5 KCMIL 397.5 KCMIL
18 18
743 18.87
431 641
More Options
PELICAN PELICAN
477 KCMIL 477 KCMIL
18 18
814 20.68
517 770
More Options
OSPREY OSPREY
556.5 KCMIL 556.5 KCMIL
18 18
879 22.33
603 898
More Options
PEACOCK PEACOCK
605 KCMIL 605 KCMIL
24 24
952 24.20
779 1159
More Options
KINGBIRD KINGBIRD
636 KCMIL 636 KCMIL
18 18
940 23.88
690 1027
More Options
COOT COOT
795 KCMIL 795 KCMIL
36 36
1040 26.42
804 1196
More Options
CANARY CANARY
900 KCMIL 900 KCMIL
54 54
1161 29.51
1158 1723
More Options
RAIL RAIL
954 KCMIL 954 KCMIL
45 45
1164 29.58
1074 1598
More Options
ORTOLAN ORTOLAN
1033.5 KCMIL 1033.5 KCMIL
45 45
1212 30.78
1163 1730
More Options
BLUEJAY BLUEJAY
1113 KCMIL 1113 KCMIL
45 45
1258 31.97
1254 1865
More Options
BUNTING BUNTING
1192.5 KCMIL 1192.5 KCMIL
45 45
1302 33.08
1342 1998
More Options
BITTERN BITTERN
1272 KCMIL 1272 KCMIL
45 45
1344 34.16
1432 2130
More Options
DIPPER DIPPER
1351.5 KCMIL 1351.5 KCMIL
45 45
1386 35.21
1521 2264
More Options
BOBOLINK BOBOLINK
1431 KCMIL 1431 KCMIL
45 45
1426 36.23
1611 2397
More Options
LAPWING LAPWING
1590 KCMIL 1590 KCMIL
45 45
1503 38.20
1790 2664
More Options
CHUKAR CHUKAR
1780 KCMIL 1780 KCMIL
84 84
1601 40.69
2072 3084
More Options
ROADRUNNER ROADRUNNER
2057 KCMIL 2057 KCMIL
76 76
1700 43.18
2243 3337
More Options
BLUEBIRD BLUEBIRD
2156 KCMIL 2156 KCMIL
84 84
1762 44.76
2508 3732
More Options
KIWI KIWI
2167 KCMIL 2167 KCMIL
72 72
1735 44.07
2300 3423
More Options
THRASHER THRASHER
2312 KCMIL 2312 KCMIL
76 76
1802 45.78
2523 3755
More Options
JOREE JOREE
2515 KCMIL 2515 KCMIL
76 76
1879 47.74
2745 4085
More Options
2839.8 KCMIL 2839.8 KCMIL
72 72
1986 50.44
3014 4485

Standards & References

Southwire's ACSR bare conductor meets or exceeds the following ASTM specifications:

  • B230 Aluminum 1350-H19 Wire for Electrical Purposes
  • B232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
  • B498 Zinc-Coated (Galvanized) Steel Core Wire for Use in Overhead Electrical Conductors.
  • B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.

Construction

  1. Aluminum 1350-H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized
  2. Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
  3. For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
  4. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease
  5. ACSR conductor is also available in non-specular.