ACSR/AW ALBARE8

Aluminum Conductor. Steel Reinforced . Bare.

Download Category Specifications
PDF Excel Table

Application & Features

Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Specifications

Select a set of products below for more information:
Codeword Size (AWG or kcmil) (mm2) No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
SPARROW SPARROW
2 AWG 2 AWG
6 6
315 8.02
87 129
More Options
RAVEN RAVEN
1/0 AWG 1/0 AWG
6 6
398 10.11
138 205
More Options
PIGEON PIGEON
3/0 AWG 3/0 AWG
6 6
501 12.74
219 326
More Options
PENGUIN PENGUIN
4/0 AWG 4/0 AWG
6 6
563 14.31
277 411
More Options
GROUSE GROUSE
80 KCMIL 80 KCMIL
8 8
367 9.32
138 205
More Options
LINNET LINNET
336.4 KCMIL 336.4 KCMIL
26 26
720 18.29
440 655
More Options
PELICAN PELICAN
477 KCMIL 477 KCMIL
18 18
814 20.68
507 754
More Options
HAWK HAWK
477 KCMIL 477 KCMIL
26 26
857 21.78
624 928
More Options
DOVE DOVE
556.5 KCMIL 556.5 KCMIL
26 26
926 23.54
728 1084
More Options
ROOK ROOK
636 KCMIL 636 KCMIL
24 24
976 24.81
785 1168
More Options
DRAKE DRAKE
795 KCMIL 795 KCMIL
26 26
1107 28.13
1041 1549
More Options
CARDINAL CARDINAL
954 KCMIL 954 KCMIL
54 54
1196 30.38
1177 1751
More Options
BLUEJAY BLUEJAY
1113 KCMIL 1113 KCMIL
45 45
1258 31.96
1222 1818
More Options
PHEASANT PHEASANT
1272 KCMIL 1272 KCMIL
54 54
1381 35.09
1568 2334
More Options
BOBOLINK BOBOLINK
1431 KCMIL 1431 KCMIL
45 45
1426 36.23
1570 2337
More Options
LAPWING LAPWING
1590 KCMIL 1590 KCMIL
45 45
1503 38.20
1746 2598
More Options
FALCON FALCON
1590 KCMIL 1590 KCMIL
54 54
1544 39.23
1960 2917

Standards & References

Southwire's ACSR bare conductor meets or exceeds the following ASTM specifications:

  • B230 Aluminum 1350-H19 Wire for Electrical Purposes
  • B232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
  • B498 Zinc-Coated (Galvanized) Steel Core Wire for Use in Overhead Electrical Conductors.
  • B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.

Construction

  1. Aluminum 1350-H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized
  2. Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
  3. For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
  4. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease
  5. ACSR conductor is also available in non-specular.