Southwire 2000V No Lead NL-EPR/SOLONON Traction Power Cable is suited for use in mass transit and general industry applications where flexibility, fire resistance, and low smoke generation are a concern. May be installed in wet or dry locations in cable trays or raceways. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Resistance to moisture and most oils, acids, and alkalis with an overall durable LSZH XLPO jacket. Meets Flame Spread and Smoke Release requirements of NFPA 130. Rated for 1000 lbs./FT maximum sidewall pressure. Alternate constructions available upon request.
| Cond. Size | Cond. Strands | Strand Class | Conductor Number | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance at 25C (ohms/1000') (ohms/km) | Max Pull Tension (lbs) (kg) | |
| More Options |
1/0 AWG
1/0 AWG
|
19
19
|
B
B
|
1
1
|
0.362
0.92
|
65
1.65
|
45
1.14
|
0.598
1.52
|
428
637
|
0.102
0.15
|
854
387.37
|
| More Options |
350 KCMIL
350 KCMIL
|
37
37
|
B
B
|
1
1
|
0.641
1.63
|
75
1.91
|
65
1.65
|
0.944
2.40
|
1296
1929
|
0.031
0.05
|
2800
1270.06
|
| More Options |
500 KCMIL
500 KCMIL
|
37
37
|
B
B
|
1
1
|
0.766
1.95
|
75
1.91
|
65
1.65
|
1.063
2.70
|
1791
2665
|
0.022
0.03
|
4000
1814.37
|
| More Options |
500 KCMIL
500 KCMIL
|
91
91
|
D
D
|
1
1
|
0.791
2.01
|
75
1.91
|
65
1.65
|
1.088
2.76
|
1798
2676
|
0.022
0.03
|
4000
1814.37
|
| More Options |
500 KCMIL
500 KCMIL
|
259
259
|
G
G
|
1
1
|
0.850
2.16
|
75
1.91
|
65
1.65
|
1.150
2.92
|
1820
2708
|
0.022
0.03
|
4000
1814.37
|
| More Options |
500 KCMIL
500 KCMIL
|
427
427
|
H
H
|
1
1
|
0.909
2.31
|
105
2.67
|
65
1.65
|
1.271
3.23
|
1961
2918
|
0.022
0.03
|
4000
1814.37
|
| More Options |
750 KCMIL
750 KCMIL
|
61
61
|
B
B
|
1
1
|
0.968
2.46
|
90
2.29
|
65
1.65
|
1.297
3.29
|
2650
3944
|
0.014
0.02
|
6000
2721.55
|
| More Options |
750 KCMIL
750 KCMIL
|
127
127
|
D
D
|
1
1
|
0.968
2.46
|
90
2.29
|
65
1.65
|
1.297
3.29
|
2650
3944
|
0.014
0.02
|
6000
2721.55
|
| More Options |
1000 KCMIL
1000 KCMIL
|
61
61
|
B
B
|
1
1
|
1.118
2.84
|
90
2.29
|
65
1.65
|
1.446
3.67
|
3498
5206
|
0.011
0.02
|
8000
3628.74
|
| More Options |
1000 KCMIL
1000 KCMIL
|
127
127
|
D
D
|
1
1
|
1.118
2.84
|
90
2.29
|
65
1.65
|
1.450
3.68
|
3468
5161
|
0.011
0.02
|
8000
3628.74
|
Thicknesses shown as Minimum Average values