CU PE/PVC SHIELDED CONTROL CABLE

Control Cable 600 Volt Copper Conductors, Polyethylene Polyvinyl Chloride (PE/PVC) Insulation Shielded Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

Download Category Specifications
PDF Excel Table

Application

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Only UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Specifications

measurement
imperial metric
Select a set of products below for more information:
Conductor Ground Wire
No. of Conductors Size (AWG or kcmil) No. of Strands Insulation Thickness (mils) (mm) Size (AWG) No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity
618969 12 12 14 AWG 14 AWG 7 7 20 0.51 684 17.38 327 487
617106 12 12 12 AWG 12 AWG 7 7 20 0.51 810 20.59 468 697
606768 2 2 10 AWG 10 AWG 7 7 20 0.51 460 11.68 154 228
619162 3 3 10 AWG 10 AWG 7 7 20 0.51 487 12.38 194 289
616984 4 4 10 AWG 10 AWG 7 7 20 0.51 636 16.17 299 445
606769 5 5 10 AWG 10 AWG 7 7 20 0.51 609 15.49 300 447
622296 7 7 10 AWG 10 AWG 7 7 20 0.51 661 16.79 388 578
662472 8 8 10 AWG 10 AWG 7 7 20 0.51 796 20.23 495 736
606770 9 9 10 AWG 10 AWG 7 7 20 0.51 772 19.62 486 723
606771 12 12 10 AWG 10 AWG 7 7 20 0.51 903 22.95 657 977

Standards & References

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • VW-1 (Vertical-Wire) Flame Test

Construction

  • Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  • Insulation:Polyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes
  • Filler:Polypropylene filler on cables with 5 or less conductors
  • Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  • Shielding:5 mils tape shield
  • Rip Chord:Rip chord for ease of jacket removal
  • Overall Jacket:Polyvinyl Chloride (PVC) Jacket
  • Color codes available upon request

Resources

There are no downloadable resources for this product.