Southwire’s 600 or 1000 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. The jacket acts as gas/vapor-tight polymeric sheath that is extruded over the core per Sections 501.15(D) and 501.15(E) of the NEC, however when these cables are used in a hazardous location, they may need to be sealed further as described in more detail in the NEC. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. VW-1 Rated\ - Sunlight Resistant - For Direct Burial - Silicone Free.
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
952459 |
2
2
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
355
9.03
|
66
99
|
|
952465 |
3
3
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
376
9.56
|
90
135
|
|
952473 |
4
4
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
409
10.41
|
110
164
|
|
952481 |
5
5
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
447
11.36
|
130
193
|
|
952499 |
6
6
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
486
12.35
|
152
226
|
|
952440 |
7
7
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
482
12.25
|
169
251
|
|
952507 |
8
8
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
559
14.20
|
208
310
|
|
952572 |
9
9
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
598
15.19
|
231
344
|
|
952598 |
12
12
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
670
17.02
|
295
439
|
|
952606 |
15
15
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
742
18.85
|
359
534
|
|
952614 |
19
19
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
780
19.81
|
439
654
|
|
952630 |
25
25
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
952
24.20
|
603
897
|
|
952648 |
30
30
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
1006
25.56
|
707
1053
|
|
952655 |
37
37
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
1083
27.52
|
849
1264
|
|
953042 |
2
2
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
388
9.87
|
88
132
|
|
953059 |
3
3
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
408
10.36
|
118
175
|
|
953067 |
4
4
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
449
11.41
|
153
227
|
|
953075 |
5
5
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
487
12.38
|
175
260
|
|
953091 |
7
7
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
561
14.26
|
248
370
|
|
953117 |
9
9
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
657
16.70
|
316
470
|
|
953125 |
10
10
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
714
18.16
|
349
520
|
|
953133 |
12
12
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
738
18.76
|
405
603
|
|
953141 |
15
15
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
819
20.81
|
496
739
|
|
953158 |
19
19
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
904
22.96
|
648
964
|
|
953174 |
25
25
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
1051
26.70
|
836
1244
|
|
953190 |
37
37
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
1198
30.44
|
1181
1758
|
|
952861 |
2
2
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
448
11.38
|
122
181
|
|
952879 |
3
3
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
459
11.67
|
163
243
|
|
952895 |
4
4
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
547
13.90
|
230
342
|
|
952887 |
5
5
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
603
15.34
|
273
406
|
|
952911 |
7
7
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
639
16.23
|
355
528
|
|
952929 |
8
8
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
711
18.08
|
408
607
|
|
952937 |
9
9
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
743
18.88
|
447
665
|
|
952952 |
12
12
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
879
22.34
|
614
913
|
|
952960 |
15
15
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
973
24.72
|
748
1114
|
|
952978 |
19
19
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
1045
26.54
|
932
1388
|
|