Southwire’s Machine Flex® tray power cables 600/1000 Volt conform to NFPA 79 and are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC® 336.10. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, Division 2 hazardous locations per NEC® Article 501 and 502. Southwire’s machine tray cable is ideal to power CNC machines, grinding, cutting, metal forming, buffing, bottling equipment, conveyors, processing & packaging equipment, assembly lines, control panels, food and beverage, oil sands, plant expansion, wind energy and data centers. Multiple approvals for multiple applications. Cable is rated for -40°C cold impact. Two conductor cables contain no green/yellow ground.
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
677315 |
3
3
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
281
7.14
|
50
75
|
|
677530 |
4
4
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
306
7.77
|
55
82
|
|
677316 |
5
5
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
332
8.43
|
75
111
|
|
677531 |
7
7
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
358
9.09
|
92
137
|
|
677532 |
9
9
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
411
10.44
|
122
182
|
|
677533 |
12
12
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
456
11.58
|
129
192
|
|
677317 |
25
25
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
635
16.13
|
255
379
|
|
677535 |
3
3
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
311
7.90
|
59
87
|
|
677536 |
4
4
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
339
8.61
|
72
107
|
|
677318 |
5
5
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
370
9.40
|
87
129
|
|
677320 |
9
9
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
462
11.73
|
164
245
|
|
677321 |
12
12
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
509
12.93
|
175
261
|
|
677258 |
3
3
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
342
8.69
|
78
116
|
|
677259 |
4
4
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
375
9.53
|
97
144
|
|
677261 |
9
9
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
516
13.11
|
222
331
|
|
677322 |
12
12
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
608
15.45
|
259
385
|
|
677262 |
18
18
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
697
17.70
|
419
624
|
|
677263 |
25
25
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
806
20.47
|
489
728
|
|
677256 |
3
3
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
389
9.89
|
109
162
|
|
677537 |
4
4
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
420
10.67
|
137
204
|
|
677538 |
5
5
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
462
11.73
|
166
246
|
|
677257 |
7
7
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
549
13.94
|
267
397
|
|
677539 |
4
4
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
502
12.75
|
204
303
|
|
677254 |
5
5
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
579
14.72
|
293
436
|
|
677255 |
7
7
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
628
15.95
|
372
554
|
|