SPEC: 45054

CU 600V XLPE Insulation Thermoplastic LSZH-TP Jacket XHHW-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free SPEC45054

Type TC-ER Control Cable 600Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket, Control Cable Conductor Identification Method 1 Table 2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free.

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. 16 AWG wire is made in accordance with UL 66 Fixture Wire. Sunlight Resistant - For Direct Burial - Silicone Free

Specifications

Select more options below for part numbers, packaging, and color options:
Cond. Size Conductor Number Cond. Strands Insulation Thickness (mils) (mm) Jacket Thickness (mils) (mm) Approx. OD (inches) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km) DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Min. Bend Radius (in) (cm) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
More Options
14 AWG 14 AWG
2 2
7 7
30 0.76
45 1.14
0.349 0.89
25 37
67 100
2.631 3.92
3.170 4.72
1.4 3.56
20 20
25 25
More Options
14 AWG 14 AWG
3 3
7 7
30 0.76
45 1.14
0.373 0.95
38 57
93 138
2.631 3.92
3.170 4.72
1.5 3.81
20 20
25 25
More Options
14 AWG 14 AWG
4 4
7 7
30 0.76
45 1.14
0.402 1.02
51 76
111 165
2.631 3.92
3.170 4.72
1.6 4.06
16 16
20 20
More Options
14 AWG 14 AWG
5 5
7 7
30 0.76
45 1.14
0.443 1.13
64 95
135 201
2.631 3.92
3.170 4.72
1.8 4.57
16 16
20 20
More Options
14 AWG 14 AWG
10 10
7 7
30 0.76
60 1.52
0.649 1.65
127 189
262 390
2.631 3.92
3.170 4.72
2.6 6.60
10 10
12 12
More Options
14 AWG 14 AWG
19 19
7 7
30 0.76
60 1.52
0.774 1.97
242 360
440 655
2.631 3.92
3.170 4.72
3.1 7.87
10 10
12 12
More Options
12 AWG 12 AWG
2 2
7 7
30 0.76
45 1.14
0.384 0.98
40 60
89 132
1.662 2.47
2.002 2.98
1.5 3.81
25 25
30 30
More Options
12 AWG 12 AWG
3 3
7 7
30 0.76
45 1.14
0.412 1.05
61 91
121 180
1.662 2.47
2.002 2.98
1.6 4.06
25 25
30 30
More Options
12 AWG 12 AWG
4 4
7 7
30 0.76
45 1.14
0.445 1.13
81 121
152 226
1.662 2.47
2.002 2.98
1.8 4.57
20 20
24 24
More Options
12 AWG 12 AWG
7 7
7 7
30 0.76
60 1.52
0.567 1.44
142 211
257 382
1.662 2.47
2.002 2.98
2.3 5.84
17 17
21 21
More Options
12 AWG 12 AWG
12 12
7 7
30 0.76
60 1.52
0.732 1.86
244 363
411 612
1.662 2.47
2.002 2.98
2.9 7.37
12 12
15 15
More Options
10 AWG 10 AWG
2 2
7 7
30 0.76
45 1.14
0.444 1.13
65 97
123 183
1.040 1.55
1.253 1.86
1.9 4.83
35 35
40 40
More Options
10 AWG 10 AWG
3 3
7 7
30 0.76
45 1.14
0.472 1.20
97 144
169 251
1.040 1.55
1.253 1.86
1.9 4.83
35 35
40 40
More Options
10 AWG 10 AWG
4 4
7 7
30 0.76
45 1.14
0.547 1.39
129 192
235 350
1.040 1.55
1.253 1.86
2.2 5.59
28 28
32 32
More Options
10 AWG 10 AWG
12 12
7 7
30 0.76
80 2.03
0.904 2.30
388 577
640 952
1.040 1.55
1.253 1.86
3.6 9.14
17 17
20 20

* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
* Ampacities have been adjusted for more than Three Current-Carrying Conductors.
! not UL listed
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 66 Fixture Wire
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Control, Thermocouple Extension, and Instrumentation Cables (applicable to sizes 20-9 AWG conductors)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Cross Linked Polyethylene (XLPE) Type XHHW-2 for cables 14 AWG or larger, 30 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Overall Jacket:Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket

Resources

There are no downloadable resources for this product.