Type MC Cable - "flame retardant sunlight resistant PVC Jacket" is suitable for use as follows:
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
552465 | 3 3 | 2/0 AWG 2/0 AWG | 12 12 | 50 1.27 | 4 4 | 1386 35.21 | 847 1260 | ||
552464 | 3 3 | 3/0 AWG 3/0 AWG | 16 16 | 50 1.27 | 4 4 | 1477 37.54 | 969 1441 | ||
593086 | 2 2 | 4/0 AWG 4/0 AWG | 19 19 | 50 1.27 | 1/0 1/0 | 1506 38.25 | 934 1390 | ||
552484 | 3 3 | 4/0 AWG 4/0 AWG | 19 19 | 50 1.27 | 2 2 | 1722 43.74 | 1297 1931 | ||
554283 | 4 4 | 4/0 AWG 4/0 AWG | 19 19 | 50 1.27 | 2 2 | 1881 47.79 | 1649 2453 | ||
599377 | 3 3 | 250 KCMIL 250 KCMIL | 22 22 | 60 1.52 | 1/0 1/0 | 1945 49.42 | 1609 2394 | ||
679730 | 4 4 | 250 KCMIL 250 KCMIL | 22 22 | 60 1.52 | 2 2 | 2033 51.65 | 1865 2775 | ||
587518 | 3 3 | 300 KCMIL 300 KCMIL | 21 21 | 60 1.52 | 1 1 | 1975 50.17 | 1717 2555 | ||
679281 | 2 2 | 350 KCMIL 350 KCMIL | 35 35 | 60 1.52 | 250 250 | 2074 52.69 | 1640 2440 | ||
560766 | 4 4 | 350 KCMIL 350 KCMIL | 35 35 | 60 1.52 | 1/0 1/0 | 2265 57.54 | 2463 3665 | ||
587515 | 3 3 | 400 KCMIL 400 KCMIL | 35 35 | 60 1.52 | 1 1 | 2167 55.05 | 2098 3122 | ||
555809 | 3 3 | 500 KCMIL 500 KCMIL | 35 35 | 60 1.52 | 1 1 | 2333 59.27 | 2467 3671 | ||
554932 | 4 4 | 500 KCMIL 500 KCMIL | 35 35 | 60 1.52 | 3/0 3/0 | 2589 65.76 | 3348 4982 | ||
560770 | 4 4 | 600 KCMIL 600 KCMIL | 41 41 | 70 1.78 | 3/0 3/0 | 2808 71.34 | 3943 5868 | ||
555812 | 3 3 | 750 KCMIL 750 KCMIL | 58 58 | 70 1.78 | 1/0 1/0 | 2786 70.78 | 3553 5288 | ||
554933 | 4 4 | 750 KCMIL 750 KCMIL | 53 53 | 70 1.78 | 3/0 3/0 | 3061 77.76 | 4705 7001 | ||
678414 | 4 4 | 900 KCMIL 900 KCMIL | 58 58 | 70 1.78 | 1/0 1/0 | 3308 84.04 | 5342 7949 |
Southwire AlumaFlex™ Type MC Cable - PVC Jacketed meets or exceeds the following requirements:
Southwire AlumaFlex™ Type MC Cable with Triple E™ Aluminum Alloy - PVC Jacketed is constructed with Aluminum Type THHN/THWN-2 conductors rated 90°C wet or dry, and a bare aluminum grounding conductor for sizes 1/0 AWG and larger. The conductors are cabled together and a binder tape is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. A black flame retardant sunlight resistant PVC jacket is applied over the armor. The jacket is available in other colors upon request, subject to economic order quantities.