MTW LW75

105°C Dry. 75°C Moisture Resistant. 600/1000 Volts. Flexible Stranded Copper Conductor. PVC Insulation

Download Category Specifications
PDF Excel Table

Application & Features

  • For use in internal wiring of electrical equipment, control panels, appliances, and grounding for use on industrial plan floor.
  • For use as permitted in NEC Article 310 and NFPA #79. For use in boat wiring in accordance with 33 CFR 183.425 - 435.

Specifications

Select a set of products below for more information:
Conductor
Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
22 AWG 22 AWG
7 7
30 0.76
91 2.31
6 8
More Options
20 AWG 20 AWG
10 10
30 0.76
99 2.51
7 11
More Options
18 AWG 18 AWG
16 16
30 0.76
106 2.69
9 14
More Options
18 AWG 18 AWG
19 19
30 0.76
106 2.69
9 14
More Options
16 AWG 16 AWG
19 19
30 0.76
117 2.97
13 19
More Options
16 AWG 16 AWG
26 26
30 0.76
117 2.97
13 19
More Options
14 AWG 14 AWG
19 19
30 0.76
132 3.35
18 27
More Options
14 AWG 14 AWG
41 41
30 0.76
132 3.35
18 27
More Options
12 AWG 12 AWG
19 19
31 0.79
151 3.84
27 40
More Options
12 AWG 12 AWG
65 65
30 0.76
151 3.84
27 40
More Options
10 AWG 10 AWG
19 19
31 0.80
175 4.45
40 60
More Options
10 AWG 10 AWG
105 105
30 0.76
175 4.45
40 60
More Options
8 AWG 8 AWG
19 19
45 1.14
238 6.05
68 102
More Options
8 AWG 8 AWG
84 84
45 1.14
247 6.27
66 99
More Options
8 AWG 8 AWG
133 133
45 1.14
252 6.40
71 106
More Options
8 AWG 8 AWG
168 168
45 1.14
257 6.53
74 110
More Options
6 AWG 6 AWG
19 19
64 1.63
306 7.77
110 164
More Options
6 AWG 6 AWG
133 133
62 1.59
324 8.23
115 172
More Options
6 AWG 6 AWG
266 266
60 1.52
335 8.51
120 179
More Options
4 AWG 4 AWG
19 19
60 1.52
355 9.02
165 245
More Options
4 AWG 4 AWG
49 49
60 1.52
359 9.12
170 254
More Options
4 AWG 4 AWG
133 133
60 1.52
387 9.83
179 267
More Options
4 AWG 4 AWG
420 420
60 1.52
378 9.60
176 261
More Options
3 AWG 3 AWG
19 19
60 1.52
395 10.03
205 305
More Options
3 AWG 3 AWG
133 133
60 1.52
410 10.41
220 327
More Options
3 AWG 3 AWG
525 525
60 1.52
400 10.16
211 315
More Options
2 AWG 2 AWG
19 19
60 1.52
417 10.59
247 368
More Options
2 AWG 2 AWG
133 133
60 1.52
472 11.99
281 418
More Options
2 AWG 2 AWG
665 665
60 1.52
428 10.87
253 377
More Options
1 AWG 1 AWG
133 133
80 2.03
535 13.59
354 526
More Options
1 AWG 1 AWG
259 259
80 2.03
521 13.23
345 513
More Options
1 AWG 1 AWG
833 833
80 2.03
516 13.11
334 497
More Options
1 AWG 1 AWG
836 836
80 2.03
540 13.72
343 510
More Options
1/0 AWG 1/0 AWG
19 19
80 2.03
532 13.51
398 592
More Options
1/0 AWG 1/0 AWG
37 37
80 2.03
527 13.39
393 585
More Options
1/0 AWG 1/0 AWG
133 133
80 2.03
561 14.25
422 628
More Options
1/0 AWG 1/0 AWG
259 259
80 2.03
561 14.25
405 602
More Options
1/0 AWG 1/0 AWG
1064 1064
80 2.03
561 14.25
420 626
More Options
2/0 AWG 2/0 AWG
19 19
80 2.03
572 14.53
488 727
More Options
2/0 AWG 2/0 AWG
37 37
80 2.03
575 14.61
486 724
More Options
2/0 AWG 2/0 AWG
133 133
80 2.03
630 16.00
532 792
More Options
2/0 AWG 2/0 AWG
259 259
80 2.03
660 16.76
557 829
More Options
2/0 AWG 2/0 AWG
1330 1330
80 2.03
614 15.60
514 765
More Options
3/0 AWG 3/0 AWG
19 19
82 2.08
617 15.67
602 896
More Options
3/0 AWG 3/0 AWG
259 259
80 2.03
666 16.92
630 937
More Options
3/0 AWG 3/0 AWG
1672 1672
80 2.03
666 16.92
627 933
More Options
4/0 AWG 4/0 AWG
37 37
80 2.03
681 17.30
746 1110
More Options
4/0 AWG 4/0 AWG
259 259
80 2.03
760 19.30
784 1166
More Options
4/0 AWG 4/0 AWG
2109 2109
80 2.03
709 18.01
765 1138
More Options
250 KCMIL 250 KCMIL
2451 2451
95 2.41
804 20.42
921 1370
More Options
350 KCMIL 350 KCMIL
37 37
95 2.41
875 22.23
1232 1833
More Options
350 KCMIL 350 KCMIL
3458 3458
95 2.41
929 23.60
1284 1911
More Options
400 KCMIL 400 KCMIL
259 259
95 2.41
985 25.02
1392 2071
More Options
500 KCMIL 500 KCMIL
5054 5054
95 2.41
1077 27.36
1767 2630

Standards & References

  • ASTM B3
  • AWM 1011/1015/1032/1230/1335
  • Voltage: 600V, AWM 10269 - 1000V
  • UL 1063 - Machine Tool Wiring (MTW); 90°C Dry, 60°C Wet/Oil
  • UL 1426 - BC-5W2; 105°C Dry, 75°C Wet
  • CSA C22.2 No. 127 - Type TEW; 105°C Dry
  • CSA C22.2 No. 210 - AWM I A/B; 105°C Dry
  • RoHS-2 Compliant
  • Oil Res I

Construction

  1. Conductors: Flexible stranded bare copper
  2. Insulation: Polyvinyl Chloride (PVC)
  3. Colors: All Colors available; Stripes available upon request.