SPEC: 53018

1/0-1064 TINNED CU AWM 3499 7500V BLACK 1000 FT SPEC53018 F1T0390400

Southwire #: F1T0390400

Download Category Specifications
PDF Excel Table
Select Product Specifications
Construction
Outer Jacket / Armor Color
BLACK
Packaging

Application & Features

Designed for Internal Wiring Appliances, where no flexing occurs, either after installation or during servicing.

  • AWM Style 3499: 150°C/7500V
  • Specifications

    Size (AWG or kcmil) (mm2) 1/0 AWG 1/0 AWG
    No. of Strands 1064 1064
    Insulation Thickness (mils) (mm) 125 3.18 mils mm
    Nom. OD (mils) (mm) 635 16.13 mils mm
    Nominal Total Weight (lbs/1000') (kgs/km) 452 672 lbs/1000' kgs/km

    Standards & References

    • ASTM B3 Soft or Annealed Copper Wire
    • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
    • ASTM B173 Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members
    • ASTM B174 Standard Specification for Bunch-Stranded Copper
    • UL 758 Standard for Appliance Wiring Material

    Construction

    1. Conductor:Flexible stranded tinned copper. Bare copper available upon request
    2. Conductor Separator:Mylar
    3. Insulation:Black Cross-Linked Polyethylene (XLPE)

    Resources

    There are no downloadable resources for this product.