600V ROYAL® SOOW Power Cord Non-UL/CSA with Black Jacket 90°C PCORD19

600 Volt, 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation and Heat, Moisture and Oil Resistant Flexible CPE Jacket, Non UL / Non CSA.

Download Category Specifications
PDF Excel Table

Application & Features

Southwire Royal® Non UL/Non CSA SOOW cord is designed for use with industrial equipment, heavy tools, battery chargers, portable lights and power extensions, suitable for outdoor applications. The cable is rated -40°C to 90°C, sunlight, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code

Specifications

Select more options below for part numbers, packaging, and color options:
Conductor
Size (AWG or kcmil) (mm2) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
More Options
8 AWG 8 AWG
2 2
133 133
615 15.62
218 325
40 40
0.72 0.72
BLACK/WHITE BLACK/WHITE
More Options
8 AWG 8 AWG
3 3
133 133
645 16.38
290 431
40 40
0.72 0.72
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
8 AWG 8 AWG
4 4
133 133
715 18.16
376 560
35 35
0.72 0.72
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
More Options
8 AWG 8 AWG
5 5
133 133
834 21.18
492 732
28 28
0.72 0.72
BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
More Options
6 AWG 6 AWG
2 2
133 133
721 18.31
337 501
55 55
0.4 0.4
BLACK/WHITE BLACK/WHITE
More Options
6 AWG 6 AWG
3 3
133 133
726 18.44
419 624
55 55
0.4 0.4
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
6 AWG 6 AWG
4 4
133 133
803 20.40
539 803
45 45
0.4 0.4
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
More Options
6 AWG 6 AWG
5 5
133 133
937 23.80
702 1044
36 36
0.4 0.4
BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
More Options
4 AWG 4 AWG
3 3
133 133
825 20.96
590 878
70 70
0.27 0.27
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
4 AWG 4 AWG
4 4
133 133
950 24.13
762 1134
60 60
0.27 0.27
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
More Options
2 AWG 2 AWG
3 3
168 168
1090 27.69
992 1477
95 95
0.16 0.16
BLACK/WHITE/GREEN BLACK/WHITE/GREEN
More Options
2 AWG 2 AWG
4 4
168 168
1290 32.77
1314 1955
80 80
0.16 0.16
BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
More Options
2 AWG 2 AWG
5 5
168 168
1373 34.87
1654 2461
64 64
0.16 0.16
BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE

Standards & References

  • ASTM B3, B174
  • NEC 400
  • MSHA
  • Federal and Military Specification JC-580B
  • RoHS-2 (European Directive 2011/65/EU )

Construction

  1. Conductors: Class K stranded bare copper per ASTM B-174
  2. Insulation: EPDM
  3. Jacket: Black CPE (Other colors available upon request)