SPEC: 13204

Southwire® CL4SS™ Class 4 Shielded Cable LS-PVC CL4P/CMP SPEC13204

Download Category Specifications
PDF Excel Table

Application & Features

Intended for use in Fault Managed Power Systems (FMPS), remote powering, indoor Class 4 circuits per 2023 National Electrical Code (NEC) article 726. For use, primarily, in Agriculture, Intelligent Buildings, and Wireless Densification. The power source (transmitter) for Class 4 circuits shall be supplied from a power source that has a voltage output of 450 volts (peak or DC) or less.

Ratings:
• Normal operating temperature: 90°C
• Temperature Range: -30°C to 90°C
• Cold bend: -30°C
• FT6 Horizontal Flame & Smoke Test

Specifications

Select more options below for part numbers, packaging, and color options:
Conductor
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
4 4
18 AWG 18 AWG
7 7
9 0.23
248 6.31
38 56
More Options
8 8
18 AWG 18 AWG
7 7
9 0.23
294 7.49
66 99
More Options
12 12
18 AWG 18 AWG
7 7
9 0.23
360 9.16
94 141
More Options
16 16
18 AWG 18 AWG
7 7
9 0.23
394 10.02
121 181
More Options
4 4
16 AWG 16 AWG
19 19
9 0.23
287 7.30
52 78
More Options
8 8
16 AWG 16 AWG
19 19
9 0.23
341 8.68
94 140
More Options
12 12
16 AWG 16 AWG
19 19
9 0.23
419 10.66
136 203
More Options
16 16
16 AWG 16 AWG
19 19
9 0.23
459 11.67
177 263
More Options
4 4
14 AWG 14 AWG
19 19
9 0.23
338 8.59
76 113
More Options
8 8
14 AWG 14 AWG
19 19
9 0.23
400 10.17
138 205
More Options
12 12
14 AWG 14 AWG
19 19
9 0.23
493 12.54
202 300
More Options
16 16
14 AWG 14 AWG
19 19
9 0.23
540 13.74
263 392

• TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Size
AWG
Capacitance
pF/ft
18 18
<30 <30
16 16
<30 <30
14 14
<30 <30
ConductorSize
num
Numberof Pairs
Black
JacketColor
White
AWG
18 18
2 2
CL4P182S0608
CL4P182S0601
18 18
4 4
CL4P184S0608
CL4P184S0601
18 18
6 6
CL4P186S0608
CL4P186S0601
18 18
8 8
CL4P188S0608
CL4P188S0601
16 16
2 2
CL4P162S0608
CL4P162S0601
16 16
4 4
CL4P164S0608
CL4P164S0601
16 16
6 6
CL4P166S0608
CL4P166S0601
16 16
8 8
CL4P168S0608
CL4P168S0601
14 14
2 2
CL4P142S0608
CL4P142S0601
14 14
4 4
CL4P144S0608
CL4P144S0601
14 14
6 6
CL4P146S0608
CL4P146S0601
14 14
8 8
CL4P148S0608
CL4P148S0601

Standards & References

  • Certified to Southwire’s UL E352061
  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 1400-2 Fault-Managed Power Systems - Part 2: Requirements for Cables

Construction

  1. Conductor:Class B or C stranded soft-drawn bare copper per ASTM B3 and B8
  2. Insulation:Twisted pair(s) with premium grade, lead-free, 90°C rated, flame retardant, Polyvinyl Chloride (PVC). Color code: Black/White, Black/Red with alpha-numeric print (1-ONE, 2-TWO)
  3. ShieldAluminum foil shield
  4. Jacket:Lead-free, 90°C rated, flame retardant, LS, Polyvinyl Chloride (PVC). See Table 3 for jacket colors.

Resources