CU FRXLPE CPE-TS CONTROL CABLE SUBSTN30

Control Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Thermoset Chlorinated Polyethylene (CPE) Jacket, Control Cable Conductor Identification Method 1 Table 2. Silicone Free

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Only UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Specifications

Select a set of products below for more information:
Conductor
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km)
More Options
2 2
14 AWG 14 AWG
7 7
30 0.76
365 9.29
73 108
More Options
3 3
14 AWG 14 AWG
7 7
30 0.76
386 9.83
91 135
More Options
4 4
14 AWG 14 AWG
7 7
30 0.76
420 10.69
113 169
More Options
5 5
14 AWG 14 AWG
7 7
30 0.76
459 11.66
133 198
More Options
7 7
14 AWG 14 AWG
7 7
30 0.76
499 12.68
173 258
More Options
9 9
14 AWG 14 AWG
7 7
30 0.76
617 15.69
238 354
More Options
12 12
14 AWG 14 AWG
7 7
30 0.76
692 17.58
303 452
More Options
15 15
14 AWG 14 AWG
7 7
30 0.76
766 19.46
369 549
More Options
19 19
14 AWG 14 AWG
7 7
30 0.76
798 20.28
448 667
More Options
4 4
12 AWG 12 AWG
7 7
30 0.76
476 12.10
154 230
More Options
9 9
12 AWG 12 AWG
7 7
30 0.76
687 17.45
326 485
More Options
12 12
12 AWG 12 AWG
7 7
30 0.76
759 19.28
414 616
More Options
15 15
12 AWG 12 AWG
7 7
30 0.76
897 22.79
547 814
More Options
2 2
10 AWG 10 AWG
7 7
30 0.76
452 11.49
121 181
More Options
4 4
10 AWG 10 AWG
7 7
30 0.76
562 14.27
228 339
More Options
12 12
10 AWG 10 AWG
7 7
30 0.76
900 22.86
624 929

Standards & References

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • VW-1 (Vertical-Wire) Flame Test

Construction

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Rip Chord:Rip chord for ease of jacket removal
  6. Overall Jacket:Thermoset Chlorinated Polyethylene (CPE) Jacket
  7. Color codes available upon request

Resources

There are no downloadable resources for this product.