For use in residential, farm and industrial water well applications where the cable is not subject to repeated handling caused by frequent servicing of the pump units. Grounded and ungrounded water well cable systems. Conductors are twisted and colored black, red, and yellow when supplied with three conductors and green ground. Cable is supplied without an overall jacket. For use within well casings.
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Ground Size | Approx. OD (inches) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
| More Options |
14 AWG
14 AWG
|
2
2
|
Solid
Solid
|
0.064
0.16
|
45
1.14
|
1 X 14
1 X 14
|
0.334
0.85
|
37
55
|
66
98
|
| More Options |
14 AWG
14 AWG
|
3
3
|
Solid
Solid
|
0.064
0.16
|
45
1.14
|
1 X 14
1 X 14
|
0.373
0.95
|
50
74
|
88
131
|
| More Options |
12 AWG
12 AWG
|
2
2
|
Solid
Solid
|
0.080
0.20
|
45
1.14
|
1 X 12
1 X 12
|
0.345
0.88
|
59
88
|
92
137
|
| More Options |
12 AWG
12 AWG
|
3
3
|
Solid
Solid
|
0.080
0.20
|
45
1.14
|
1 X 12
1 X 12
|
0.414
1.05
|
79
118
|
122
182
|
| More Options |
10 AWG
10 AWG
|
2
2
|
Solid
Solid
|
0.101
0.26
|
45
1.14
|
1 X 10
1 X 10
|
0.414
1.05
|
95
141
|
131
195
|
| More Options |
10 AWG
10 AWG
|
3
3
|
Solid
Solid
|
0.101
0.26
|
45
1.14
|
1 X 10
1 X 10
|
0.462
1.17
|
126
188
|
176
262
|
| More Options |
8 AWG
8 AWG
|
2
2
|
19
19
|
0.143
0.36
|
45
1.14
|
1 X 10
1 X 10
|
0.574
1.46
|
135
201
|
195
290
|
| More Options |
8 AWG
8 AWG
|
3
3
|
19
19
|
0.143
0.36
|
45
1.14
|
1 X 10
1 X 10
|
0.610
1.55
|
186
277
|
274
408
|
| More Options |
6 AWG
6 AWG
|
3
3
|
19
19
|
0.179
0.45
|
60
1.52
|
1 X 8
1 X 8
|
0.700
1.78
|
296
440
|
402
598
|
| More Options |
4 AWG
4 AWG
|
3
3
|
19
19
|
0.226
0.57
|
60
1.52
|
1 X 8
1 X 8
|
0.792
2.01
|
442
658
|
564
839
|
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
| Cond. Size | Conductor Number | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | Allowable Ampacity Raceway 75C |
|
14 AWG
14 AWG
|
2
2
|
2.631
3.92
|
3.170
4.72
|
0.058
0.09
|
65
29.48
|
1.3
3.30
|
20
20
|
|
14 AWG
14 AWG
|
3
3
|
2.631
3.92
|
3.170
4.72
|
0.058
0.09
|
98
44.45
|
1.5
3.81
|
20
20
|
|
12 AWG
12 AWG
|
2
2
|
1.662
2.47
|
2.002
2.98
|
0.054
0.08
|
104
47.17
|
1.4
3.56
|
25
25
|
|
12 AWG
12 AWG
|
3
3
|
1.662
2.47
|
2.002
2.98
|
0.054
0.08
|
156
70.76
|
1.7
4.32
|
25
25
|
|
10 AWG
10 AWG
|
2
2
|
1.040
1.55
|
1.253
1.86
|
0.050
0.07
|
166
75.30
|
1.7
4.32
|
35
35
|
|
10 AWG
10 AWG
|
3
3
|
1.040
1.55
|
1.253
1.86
|
0.050
0.07
|
249
112.94
|
1.8
4.57
|
35
35
|
|
8 AWG
8 AWG
|
2
2
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
264
119.75
|
2.3
5.84
|
50
50
|
|
8 AWG
8 AWG
|
3
3
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
396
179.62
|
2.4
6.10
|
50
50
|
|
6 AWG
6 AWG
|
3
3
|
0.411
0.61
|
0.495
0.74
|
0.051
0.08
|
629
285.31
|
2.8
7.11
|
65
65
|
|
4 AWG
4 AWG
|
3
3
|
0.258
0.38
|
0.310
0.46
|
0.048
0.07
|
1001
454.05
|
3.2
8.13
|
85
85
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing.