SPEC: 87100

Tracer Wire SPEC87100

Download Category Specifications
PDF Excel Table

Application & Features

  • Used on golf course sprinkler, gas lines, direct burial applications, also can be used for animal containment
  • 45 mil Linear Low Density Polyethylene LLDPE insulation thickness.
  • Rated for 60ºC
  • Rated for 600 volt
  • For direct burial
  • Specifications

    Select more options below for part numbers, packaging, and color options:
    Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Approx. OD (inches) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
    More Options
    18 AWG 18 AWG
    1 1
    Solid Solid
    45 1.14
    0.134 0.34
    10 15
    More Options
    16 AWG 16 AWG
    1 1
    Solid Solid
    0.050 0.13
    45 1.14
    0.144 0.37
    8 12
    14 21
    More Options
    14 AWG 14 AWG
    1 1
    Solid Solid
    0.064 0.16
    45 1.14
    0.157 0.40
    13 19
    19 28
    More Options
    12 AWG 12 AWG
    1 1
    Solid Solid
    0.080 0.20
    45 1.14
    0.174 0.44
    20 30
    27 40
    More Options
    10 AWG 10 AWG
    1 1
    Solid Solid
    0.101 0.26
    45 1.14
    0.193 0.49
    32 48
    40 60
    More Options
    8 AWG 8 AWG
    1 1
    Solid Solid
    0.128 0.33
    45 1.14
    0.222 0.56
    50 74
    60 89
    Cond. Size Conductor Number DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Min. Bend Radius (in) (cm) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
    18 AWG 18 AWG
    1 1
    16 AWG 16 AWG
    1 1
    4.181 6.22
    5.282 7.86
    1.1 2.79
    - -
    18 18
    14 AWG 14 AWG
    1 1
    2.631 3.92
    3.323 4.95
    1.2 3.05
    20 20
    25 25
    12 AWG 12 AWG
    1 1
    1.662 2.47
    2.100 3.13
    1.3 3.30
    25 25
    30 30
    10 AWG 10 AWG
    1 1
    1.040 1.55
    1.314 1.96
    1.5 3.81
    35 35
    40 40
    8 AWG 8 AWG
    1 1
    0.653 0.97
    0.824 1.23
    1.7 4.32
    50 50
    55 55
    Insulation Color Application Part Number
    18 AWG 18 AWG
    16 AWG 16 AWG
    14 AWG 14 AWG
    12 AWG 12 AWG
    10 AWG 10 AWG
    8 AWG 8 AWG
    Red Red
    Electrical Power Line Electrical Power Line
    54489__04 54489__04
    54490__04 54490__04
    54491__04 54491__04
    Orange Orange
    Fiber Optic / Telecom Fiber Optic / Telecom
    54490__03 54490__03
    54491__03 54491__03
    Yellow Yellow
    Natural Gas Pipeline Natural Gas Pipeline
    54489__02 54489__02
    54490__02 54490__02
    54491__02 54491__02
    54492__02 54492__02
    54494__02 54494__02
    Blue Blue
    Potable Water Pipeline Potable Water Pipeline
    54489__06 54489__06
    54491__06 54491__06
    54492__06 54492__06
    54493__06 54497__06 54493__06 54497__06
    Purple Purple
    Reclaimed Water, Irrigation, or Slurry Lines Reclaimed Water, Irrigation, or Slurry Lines
    54490__13 54490__13
    54492__07 54492__07
    Green Green
    Sewer Pipeline Sewer Pipeline
    54489__05 54489__05
    54490__05 54490__05
    54492__05 54492__05
    54493__05 54493__05
    Black Black
    Pet Containment / Invisible Fence Pet Containment / Invisible Fence
    54490__08 54490__08
    54491__08 54491__08
    54492__08 54492__08
    White White
    Pet Containment / Other / Misc Pet Containment / Other / Misc
    54490__01 54490__01
    54491__01 54491__01
    Brown Brown
    Pet Containment / Other / Misc Pet Containment / Other / Misc
    54493__07 54493__07

    Standards & References

    • ASTM B3 Soft or Annealed Copper Wire
    • UL 2989 Tracer Wire

    Construction

    1. Conductor:Solid bare copper per ASTM B3
    2. Insulation:Linear Low Density Polyethylene (LLDPE)

    Resources