SPEC: 87100

Tracer Wire SPEC87100

Download Category Specifications
PDF Excel Table

Application & Features

  • Used on golf course sprinkler, gas lines, direct burial applications, also can be used for animal containment
  • 45 mil Linear Low Density Polyethylene LLDPE insulation thickness.
  • Rated for 60ºC
  • Rated for 600 volt
  • For direct burial
  • Specifications

    Select a set of products below for more information:
    Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Approx. OD (in) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
    More Options
    18 AWG 18 AWG
    1 1
    Solid Solid
    45 1.14
    0.134 0.34
    10 15
    More Options
    16 AWG 16 AWG
    1 1
    Solid Solid
    0.050 0.13
    45 1.14
    0.144 0.37
    8 12
    14 21
    More Options
    14 AWG 14 AWG
    1 1
    Solid Solid
    0.064 0.16
    45 1.14
    0.157 0.40
    13 19
    19 28
    More Options
    12 AWG 12 AWG
    1 1
    Solid Solid
    0.080 0.20
    45 1.14
    0.174 0.44
    20 30
    27 40
    More Options
    10 AWG 10 AWG
    1 1
    Solid Solid
    0.101 0.26
    45 1.14
    0.193 0.49
    32 48
    40 60
    More Options
    8 AWG 8 AWG
    1 1
    Solid Solid
    0.128 0.33
    45 1.14
    0.222 0.56
    50 74
    60 89
    Cond. Size Conductor Number DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Min. Bend Radius (in) (cm) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
    18 AWG 18 AWG
    1 1
    16 AWG 16 AWG
    1 1
    4.181 6.22
    5.282 7.86
    1.1 2.79
    - -
    18 18
    14 AWG 14 AWG
    1 1
    2.631 3.92
    3.323 4.95
    1.2 3.05
    20 20
    25 25
    12 AWG 12 AWG
    1 1
    1.662 2.47
    2.100 3.13
    1.3 3.30
    25 25
    30 30
    10 AWG 10 AWG
    1 1
    1.040 1.55
    1.314 1.96
    1.5 3.81
    35 35
    40 40
    8 AWG 8 AWG
    1 1
    0.653 0.97
    0.824 1.23
    1.7 4.32
    50 50
    55 55
    Insulation Color Application 18 AWG 16 AWG 14 AWG 12 AWG 10 AWG 8 AWG
    Red Red
    Electrical Power Line Electrical Power Line
    X X
    X X
    Yellow Yellow
    Natural Gas Pipeline Natural Gas Pipeline
    X X
    X X
    X X
    x x
    Green Green
    Sewer Pipeline Sewer Pipeline
    X X
    X X
    X X
    X X
    Blue Blue
    Potable Water Pipeline Potable Water Pipeline
    X X
    X X
    X X
    X X
    Purple Purple
    Reclaimed Water, Irrigation, or Slurry Lines Reclaimed Water, Irrigation, or Slurry Lines
    X X
    Black Black
    Pet Containment / Invisible Fence Pet Containment / Invisible Fence
    X X
    X X

    Standards & References

    • ASTM B3 Soft or Annealed Copper Wire
    • UL 2989 Tracer Wire

    Construction

    1. Conductor:Solid bare copper per ASTM B3
    2. Insulation:Linear Low Density Polyethylene (LLDPE)

    Resources

    There are no downloadable resources for this product.