SPEC: 13070

Multi Conductor CL3P/FPLP/CMP Non-Shielded SPEC13070

300V, 75°C, Multi-Conductor, Non-Shielded, Stranded Copper, CL3P/FPLP/CMP. Minimum Operating Temperature -10°C, Maximum Operating Temperature 75°C

Download Category Specifications
PDF Excel Table

Application & Features

For use in Remote Control, Signaling, and Power-Limited circuits per NEC Article 725. Sizes 22 AWG - 16 AWG can also be used as communication circuits per NEC Article 800. Can be used in security, sound and audio, speaker cable, public address, intercom, sound reinforcement, alarm and access control circuits and power-limited controls. The conductors are cabled together; lay length varies depending on conductor count and gauge size.

Specifications

Select more options below for part numbers, packaging, and color options:
Cable Type Cond. Size Conductor Number Cond. Type Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km) Shield Type Application DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km)
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
22 AWG 22 AWG
2 2
CU CU
7 7
0.022 0.06
5 0.13
15 0.38
0.118 0.30
4 6
8 12
None None
16.720 24.88
20.150 29.99
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
22 AWG 22 AWG
4 4
CU CU
7 7
0.022 0.06
5 0.13
15 0.38
0.136 0.35
8 12
15 22
None None
16.720 24.88
20.150 29.99
0.030 0.04
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
22 AWG 22 AWG
6 6
CU CU
7 7
0.022 0.06
5 0.13
15 0.38
0.163 0.41
13 19
21 31
None None
16.720 24.88
20.150 29.99
0.030 0.04
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
22 AWG 22 AWG
12 12
CU CU
7 7
0.022 0.06
5 0.13
15 0.38
0.216 0.55
26 39
40 60
None None
16.720 24.88
20.150 29.99
0.030 0.04
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
20 AWG 20 AWG
2 2
CU CU
7 7
0.036 0.09
5 0.13
15 0.38
0.132 0.34
6 9
12 18
None None
10.500 15.63
12.650 18.83
0.027 0.04
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
2 2
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.152 0.39
10 15
16 24
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
3 3
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.160 0.41
15 22
23 34
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
4 4
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.181 0.46
20 30
30 45
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
6 6
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.217 0.55
30 45
43 64
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
8 8
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.237 0.60
40 60
56 83
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
18 AWG 18 AWG
10 10
CU CU
7 7
0.045 0.11
5 0.13
15 0.38
0.280 0.71
50 74
70 104
None None
6.669 9.92
8.035 11.96
0.036 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
16 AWG 16 AWG
2 2
CU CU
19 19
0.056 0.14
5 0.13
15 0.38
0.174 0.44
16 24
23 34
None None
4.181 6.22
5.037 7.50
0.033 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
16 AWG 16 AWG
4 4
CU CU
19 19
0.056 0.14
5 0.13
15 0.38
0.201 0.51
32 48
42 63
None None
4.181 6.22
5.037 7.50
0.033 0.05
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
14 AWG 14 AWG
2 2
CU CU
19 19
0.07 0.18
5 0.13
15 0.38
0.200 0.51
25 37
33 49
None None
2.631 3.92
3.170 4.72
0.058 0.09
More Options
CL3P/FPLP/CMP CL3P/FPLP/CMP
12 AWG 12 AWG
2 2
CU CU
19 19
0.088 0.22
5 0.13
15 0.38
0.251 0.64
40 60
52 77
None None
Security and Access Control Security and Access Control
1.662 2.47
2.002 2.98
0.054 0.08

Standards & References

  • UL 1424 Cables for Power-Limited Fire-Alarm Circuits
  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 13 Power-Limited Circuit Cables
  • UL 444 Communications Cables (22 AWG - 16 AWG)
  • NFPA 262

Construction

  1. Conductor:Stranded bare copper per ASTM B3 and B8
  2. Insulation:Low Smoke Polyvinyl Chloride (LS-PVC)
  3. Rip Cord:Rip cord for ease of jacket removal
  4. Jacket:White Low Smoke Polyvinyl Chloride (LS-PVC)

Resources

There are no downloadable resources for this product.