For use in High Speed Rail systems of domestic and international standard application, primarily as electro-mechanical current carrying cable and wire for overhead contact systems (OCS). Southwire’s messenger wire is designed for long service life with the ability to maintain rugged strength through sustained performance.
| Cond. Size | Cond. Strands | Strand Class | Conductor Number | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance at 25C (ohms/1000') (ohms/km) | Max Pull Tension (lbs) (kg) | |
| More Options |
25 MMSQ
25 MMSQ
|
7
7
|
B
B
|
1
1
|
0.184
0.47
|
81
121
|
0.417
0.62
|
959
434.99
|
| More Options |
6 MMSQ
6 MMSQ
|
7
7
|
B
B
|
1
1
|
0.184
0.47
|
81
121
|
0.417
0.62
|
959
434.99
|
| More Options |
120 MMSQ
120 MMSQ
|
19
19
|
B
B
|
1
1
|
0.184
0.47
|
81
121
|
0.417
0.62
|
959
434.99
|
| Stock Code | Nominal Cross Section (mm²) | Calculated Cross Section (mm²) | Number of Wires | Diameter per Wire (mm) | Calculated Conductor Diameter (mm) | Weight (kg/km) | Breaking Load (kN) | Continuous Current Carrying Capacity (A) |
|
TBA
TBA
|
10
10
|
10.02
10.02
|
7
7
|
1.35
1.35
|
4.1
4.1
|
90
90
|
5.88
5.88
|
75
75
|
|
TBA
TBA
|
16
16
|
15.89
15.89
|
7
7
|
1.70
1.70
|
5.1
5.1
|
143
143
|
9.33
9.33
|
100
100
|
|
25
25
|
24.25
24.25
|
7
7
|
2.10
2.10
|
6.3
6.3
|
218
218
|
14.24
14.24
|
130
130
|
|
|
TBA
TBA
|
35
35
|
34.36
34.36
|
7
7
|
2.50
2.50
|
7.5
7.5
|
310
310
|
20.17
20.17
|
160
160
|
|
TBA
TBA
|
50
50
|
49.48
49.48
|
7
7
|
3.00
3.00
|
9.0
9.0
|
446
446
|
28.58
28.58
|
200
200
|
|
TBA
TBA
|
50
50
|
48.35
48.35
|
19
19
|
1.80
1.80
|
9.0
9.0
|
437
437
|
28.39
28.39
|
200
200
|
|
70
70
|
65.81
65.81
|
19
19
|
2.10
2.10
|
10.5
10.5
|
596
596
|
38.64
38.64
|
245
245
|
|
|
726691
726691
|
95
95
|
93.27
93.27
|
19
19
|
2.50
2.50
|
12.5
12.5
|
845
845
|
54.76
54.76
|
305
305
|
|
120
120
|
116.99
116.99
|
19
19
|
2.80
2.80
|
14.0
14.0
|
1060
1060
|
67.57
67.57
|
350
350
|
|
|
TBA
TBA
|
150
150
|
147.11
147.11
|
37
37
|
2.25
2.25
|
15.8
15.8
|
1337
1337
|
86.37
86.37
|
410
410
|
|
TBA
TBA
|
185
185
|
181.62
181.62
|
37
37
|
2.50
2.50
|
17.5
17.5
|
1649
1649
|
106.63
106.63
|
465
465
|
|
TBA
TBA
|
240
240
|
242.54
242.54
|
61
61
|
2.25
2.25
|
20.3
20.3
|
2209
2209
|
142.40
142.40
|
560
560
|
|
TBA
TBA
|
300
300
|
299.43
299.43
|
61
61
|
2.50
2.50
|
22.5
22.5
|
2725
2725
|
175.80
175.80
|
635
635
|
|
TBA
TBA
|
400
400
|
400.14
400.14
|
61
61
|
2.89
2.89
|
26.0
26.0
|
3640
3640
|
231.12
231.12
|
765
765
|
|
TBA
TBA
|
500
500
|
499.83
499.83
|
61
61
|
3.23
3.23
|
29.1
29.1
|
4545
4545
|
288.70
288.70
|
880
880
|
Bronze BzII (CuMg) stranded conductor per DIN 48201 part 2