RHINOSHIELDTM Type SHD-GC is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers. It is also an excellent choice for shovels, draglines, dredges, cranes and marine shore-to-ship power supplies, and anytime extra-durable, flexible cable is required. Suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground Check Size | Inner Jacket Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (inches) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
| More Options |
1 AWG
1 AWG
|
3
3
|
385
385
|
0.347
0.88
|
110
2.79
|
0.627
1.59
|
8
8
|
90
2.29
|
125
3.18
|
1.963
4.99
|
2623
3903
|
| More Options |
500 KCMIL
500 KCMIL
|
3
3
|
1221
1221
|
0.900
2.29
|
125
3.18
|
1.188
3.02
|
6
6
|
120
3.05
|
185
4.70
|
3.356
8.52
|
8833
13145
|
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
| Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Rated Strength (lbs) (kg) | Min. Bend Radius (in) (cm) | Allowable Ampacity In Air 90C | |
| More Options |
1 AWG
1 AWG
|
0.143
0.21
|
0.180
0.27
|
0.035
0.05
|
572
259.45
|
15.7
39.88
|
184
184
|
| More Options |
500 KCMIL
500 KCMIL
|
0.024
0.04
|
0.034
0.05
|
0.026
0.04
|
3420
1551.28
|
26.8
68.07
|
536
536
|
* Ampacities based upon ICEA S-75-381 Table H-1.
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.