SPEC: 47802

3/C CU 5KV 100% & 133% XLPE/PVC RHINOPOWERTM Type MP-GC. MSHA Approved SPEC47802

Class B Copper conductors, Cross-Linked Polyethylene (XLP) 100% & 133% Insulation Level, Copper Tape Shield, Polyvinyl Chloride (PVC) Jacket, 90°C

Download Category Specifications
PDF Excel Table

Application & Features

RHINOPOWERTM Type MP-GC mine power feeder cable is a heavy-duty power cable for use in stationary horizontal HV mine power distribution circuits, for permanent or semi-portable applications with power transmission in deep mines, surface mines, open pits, tunnels, in conduit or duct (not to exceed max rated voltage), and suitable for direct burial in wet or dry locations. For vertical drop requirements consult with factory application specialist.

Specifications

Select more options below for part numbers, packaging, and color options:
Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground Check Size Jacket Thickness (mils) (mm) Approx. OD (inches) (cm) Approx. Weight (lbs/1000') (kgs/km)
More Options
4 AWG 4 AWG
3 3
7 7
0.212 0.54
90 2.29
0.440 1.12
8 8
110 2.79
1.320 3.35
1158 1723
More Options
2 AWG 2 AWG
3 3
7 7
0.268 0.68
90 2.29
0.478 1.21
8 8
115 2.92
1.565 3.98
1686 2509
More Options
1 AWG 1 AWG
3 3
19 19
0.298 0.76
90 2.29
0.506 1.29
8 8
110 2.79
1.530 3.89
1779 2647
More Options
1/0 AWG 1/0 AWG
3 3
19 19
0.336 0.85
90 2.29
0.546 1.39
8 8
160 4.06
1.630 4.14
2149 3198

* Strand count meets minimum number per ASTM
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Cond. Size DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Capacitive Reactance (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km) Rated Strength (lbs) (kg) Min. Bend Radius (in) (cm) Allowable Ampacity In Air 90C
More Options
4 AWG 4 AWG
0.258 0.38
0.325 0.48
0.049 0.07
0.038 0.06
285 129.27
15.8 40.13
122 122
More Options
2 AWG 2 AWG
0.162 0.24
0.204 0.30
0.039 0.06
0.035 0.05
453 205.48
18.7 47.50
159 159
More Options
1 AWG 1 AWG
0.128 0.19
0.162 0.24
0.036 0.05
0.034 0.05
572 259.45
18.3 46.48
184 184
More Options
1/0 AWG 1/0 AWG
0.102 0.15
0.128 0.19
0.033 0.05
0.033 0.05
722 327.49
19.5 49.53
211 211

* Ampacities based upon ICEA S-75-381 Table I-1.
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • ICEA S-75-381 Portable and Power Feeder Cables for Use in Mines
  • MSHA Approved

Construction

  1. Conductor:Class B compact stranded bare copper per ASTM B3 and ASTM B496
  2. Conductor Shield:Semi-conducting cross-linked copolymer
  3. Insulation:Cross-Linked Polyethylene (XLP) 100% and 133% Insulation Level
  4. Insulation Shield:Strippable semi-conducting cross-linked copolymer
  5. Copper Tape Shield:Helically wrapped 5 mil copper tape with 25% overlap
  6. Grounding Conductors:Two Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  7. Ground Check:Class B compressed stranded bare copper per ASTM B3 and ASTM B8 with yellow high strength, polypropylene insulation
  8. Filler:Rubber Fillers as needed
  9. Reinforcement:Tape and Reinforcing twine applied over the core for improved mechanical integrity and ease of stripping
  10. Jacket:Black Polyvinyl Chloride (PVC). Alternate jacket colors available.
  11. Reflective Stripe:Highly visible reflective stripe embedded into the outer jacket to increase safety and help prevent cable runover (optional, contact your sales representative for part number)