For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
562239 |
2
2
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
660
16.77
|
196
291
|
|
561778 |
25
25
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1373
34.89
|
900
1340
|
|
561781 |
4
4
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
715
18.16
|
246
366
|
|
561788 |
5
5
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
753
19.13
|
274
408
|
|
562248 |
6
6
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
792
20.14
|
304
452
|
|
561789 |
7
7
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
792
20.14
|
323
480
|
|
562254 |
8
8
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
864
21.97
|
375
559
|
|
562258 |
10
10
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
956
24.29
|
440
655
|
|
561790 |
12
12
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
977
24.83
|
481
716
|
|
562263 |
15
15
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1044
26.52
|
554
825
|
|
561791 |
19
19
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1199
30.45
|
694
1033
|
|
562269 |
20
20
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1226
31.14
|
721
1074
|
|
561778 |
25
25
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1373
34.89
|
900
1340
|
|
562275 |
30
30
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1428
36.27
|
1009
1501
|
|
561792 |
2
2
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
695
17.66
|
223
332
|
|
561792 |
2
2
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
695
17.66
|
222
331
|
|
561794 |
4
4
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
757
19.24
|
292
435
|
|
589296 |
5
5
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
800
20.33
|
330
492
|
|
567116 |
6
6
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
876
22.27
|
393
585
|
|
568599 |
8
8
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
923
23.45
|
461
687
|
|
563506 |
10
10
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1026
26.08
|
547
814
|
|
563511 |
15
15
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1285
32.65
|
814
1211
|
|
563515 |
20
20
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1375
34.94
|
978
1456
|
|
587679 |
30
30
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
14
14
|
|
1515
38.48
|
1296
1928
|
|
562290 |
2
2
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
747
18.97
|
273
406
|
|
561797 |
3
3
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
775
19.69
|
320
476
|
|
561798 |
4
4
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
819
20.83
|
372
553
|
|
567109 |
6
6
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
948
24.08
|
503
748
|
|
584443 |
8
8
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
1008
25.62
|
602
896
|
|
567096 |
10
10
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
1274
32.36
|
816
1214
|
|
589343 |
12
12
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
1301
33.07
|
909
1352
|
|
567102 |
15
15
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
12
12
|
|
1407
35.74
|
1069
1591
|
|