SPEC: 48003

CU 600V or 1000V LSZH XHHW-2 SOLONONplus™ Living Building Challenge™ (LBC) Red List Free SPEC48003

SOLONONplus™ 600Volt or 1000V Single Conductor Copper Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Insulation Type XHHW-2

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt or 1000 Volt SOLONONplus™ Type XHHW-2 cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, and aerially when supported by a messenger. These cables are ideal for use in establishments where low smoke and low acid emissions are desired for public safety and health and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

a. The conductors are available in tinned and flexible copper stranding upon request.
b. NEC compliant
c. The halogen content is less than 0.2% and Acid gas less than 2.0%
d. Passes UL VW-1
e. 70,000 BTU/Hr. Vertical Flame Test
f. UL listed for CT use on 1/0 and Larger
g. UL listed FT4/IEEE 1202 and ST-1 (#2 and larger)
h. -40°C Cold impact and cold bend
i. Oil Resistant I and II
j. UV/Sunlight resistant
k. Color Available upon request
l.PRI oil resistance at 60°C
m.PRII oil resistance at 75°C
n.GRI gasoline and oil resistance
o.GRII gasoline and oil resistance
p. REACH & RoHS compliant
q. Listed and marked HAL-FREE (Halogen Free) per CSA 2556-15
r. Living Building Challenge™ (LBC) Red List Free

Specifications

Select more options below for part numbers, packaging, and color options:
Cond. Size Cond. Strands Strand Class Conductor Number Insulation Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) DC Resistance at 25C (ohms/1000') (ohms/km) Max Pull Tension (lbs) (kg)
More Options
10 AWG 10 AWG
7 7
B B
1 1
30 0.76
0.177 0.45
42 63
1.040 1.55
More Options
8 AWG 8 AWG
7 7
B B
1 1
45 1.14
0.236 0.60
71 106
0.653 0.97
132 59.87
More Options
6 AWG 6 AWG
7 7
B B
1 1
45 1.14
0.272 0.69
105 156
0.411 0.61
209 94.80
More Options
4 AWG 4 AWG
7 7
B B
1 1
45 1.14
0.319 0.81
158 235
0.258 0.38
333 151.05
More Options
3 AWG 3 AWG
7 7
B B
1 1
45 1.14
0.346 0.88
195 290
0.205 0.31
420 190.51
More Options
2 AWG 2 AWG
7 7
B B
1 1
45 1.14
0.371 0.94
240 357
0.162 0.24
530 240.40
More Options
1/0 AWG 1/0 AWG
19 19
B B
1 1
55 1.40
0.478 1.21
382 568
0.102 0.15
844 382.83
More Options
2/0 AWG 2/0 AWG
19 19
B B
1 1
55 1.40
0.522 1.33
473 704
0.081 0.12
1064 482.62
More Options
3/0 AWG 3/0 AWG
19 19
B B
1 1
55 1.40
0.572 1.45
588 875
0.064 0.10
1342 608.72
More Options
4/0 AWG 4/0 AWG
19 19
B B
1 1
55 1.40
0.614 1.56
729 1085
0.051 0.08
1692 767.48
More Options
250 KCMIL 250 KCMIL
37 37
B B
1 1
65 1.65
0.678 1.72
867 1290
0.043 0.06
2000 907.18
More Options
350 KCMIL 350 KCMIL
37 37
B B
1 1
65 1.65
0.777 1.97
1192 1774
0.031 0.05
2800 1270.06
More Options
500 KCMIL 500 KCMIL
37 37
B B
1 1
65 1.65
0.902 2.29
1676 2494
0.022 0.03
4000 1814.37
More Options
600 KCMIL 600 KCMIL
61 61
B B
1 1
80 2.03
1.034 2.63
2036 3030
0.018 0.03
4800 2177.24

Tinned Copper Conductor
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Size Color Stock Code
2/0 2/0
Green Green
673896 673896

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B170 Oxygen Free Electrolytic Copper (available upon request)
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2885 Acid Gas, Acidity and conductivity of combusted materials and assessment of halogens
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA T-33-655/MIL-C-24643 Low Smoke Halogen Free (LSHF) Polymeric Jackets
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • ISO 9001 Quality management
  • ISO 14001 Environmental management systems standard
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (2 AWG and larger)
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways (non-emergency circuits only)

Construction

  1. Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation:SOLONONplus™ Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Type XHHW-2

Resources

There are no downloadable resources for this product.