SPEC: 45253

CU 600/1000V XLPE Insulation Thermoplastic CPE-TP Jacket XHHW-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free SPEC45253

Type TC-ER Power Cable 600 or 1000 Volt Three Conductor Copper, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket with 1 Bare CU Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt Type TC-ER power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free

Specifications

Select more options below for part numbers, packaging, and color options:
Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Ground Size Jacket Thickness (mils) (mm) Approx. OD (inches) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
More Options
8 AWG 8 AWG
3 3
7 7
0.142 0.36
45 1.14
1x10 1x10
110 2.79
0.784 1.99
187 278
404 601
More Options
6 AWG 6 AWG
3 3
7 7
0.178 0.45
45 1.14
1x8 1x8
110 2.79
0.87 2.21
297 442
547 814
More Options
4 AWG 4 AWG
3 3
7 7
0.225 0.57
45 1.14
1x8 1x8
110 2.79
0.917 2.33
442 658
703 1046
More Options
2 AWG 2 AWG
3 3
7 7
0.283 0.72
45 1.14
1x6 1x6
110 2.79
1.054 2.68
703 1046
1033 1537
More Options
1/0 AWG 1/0 AWG
3 3
19 19
0.362 0.92
55 1.40
1x6 1x6
110 2.79
1.262 3.21
1070 1592
1487 2213
More Options
3/0 AWG 3/0 AWG
3 3
19 19
0.456 1.16
55 1.40
1x4 1x4
110 2.79
1.484 3.77
1700 2530
2221 3305
More Options
4/0 AWG 4/0 AWG
3 3
19 19
0.512 1.30
55 1.40
1x4 1x4
110 2.79
1.579 4.01
2110 3140
2652 3947
More Options
250 KCMIL 250 KCMIL
3 3
37 37
0.558 1.42
65 1.65
1x4 1x4
110 2.79
1.713 4.35
2469 3674
3091 4600
More Options
350 KCMIL 350 KCMIL
3 3
37 37
0.661 1.68
65 1.65
1x3 1x3
110 2.79
1.927 4.89
3439 5118
4175 6213
More Options
600 KCMIL 600 KCMIL
3 3
61 61
0.866 2.20
80 2.03
1x3/0 1x3/0
110 2.79
2.426 6.16
6136 9131
7069 10520
More Options
750 KCMIL 750 KCMIL
3 3
61 61
0.968 2.46
80 2.03
1x1 1x1
110 2.79
2.64 6.71
7277 10829
8399 12499

GG: Green Insulated Ground
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Cond. Size Conductor Number Min. Bend Radius (in) (cm) Max Pull Tension (lbs) (kg) DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
More Options
8 AWG 8 AWG
3 3
3.1 7.87
396 179.62
0.653 0.97
0.810 1.21
0.052 0.08
50 50
55 55
More Options
6 AWG 6 AWG
3 3
3.5 8.89
629 285.31
0.411 0.61
0.510 0.76
0.051 0.08
65 65
75 75
More Options
4 AWG 4 AWG
3 3
3.7 9.40
1001 454.05
0.258 0.38
0.320 0.48
0.048 0.07
85 85
95 95
More Options
2 AWG 2 AWG
3 3
5.3 13.46
1592 722.12
0.162 0.24
0.201 0.30
0.045 0.07
115 115
130 130
More Options
1/0 AWG 1/0 AWG
3 3
6.3 16.00
2534 1149.40
0.102 0.15
0.127 0.19
0.044 0.07
150 150
170 170
More Options
3/0 AWG 3/0 AWG
3 3
7.4 18.80
4027 1826.61
0.064 0.10
0.079 0.12
0.042 0.06
200 200
225 225
More Options
4/0 AWG 4/0 AWG
3 3
7.9 20.07
5078 2303.34
0.051 0.08
0.063 0.09
0.041 0.06
230 230
260 260
More Options
250 KCMIL 250 KCMIL
3 3
8.6 21.84
6000 2721.55
0.043 0.06
0.053 0.08
0.041 0.06
255 255
290 290
More Options
350 KCMIL 350 KCMIL
3 3
9.6 24.38
8400 3810.17
0.031 0.05
0.039 0.06
0.040 0.06
310 310
350 350
More Options
600 KCMIL 600 KCMIL
3 3
14.6 37.08
14400 6531.72
0.018 0.03
0.024 0.04
0.039 0.06
420 420
475 475
More Options
750 KCMIL 750 KCMIL
3 3
15.8 40.13
18000 8164.66
0.014 0.02
0.019 0.03
0.038 0.06
475 475
535 535

* Ampacities based upon 2023 NEC Table 310.16. See NEC sections 310.15 and 110.14(C) for additional requirements.

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  1. Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation:Cross Linked Polyethylene (XLPE) Type XHHW-2
  3. Grounding Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (cable size 8 & 6 has insulated green ground)
  4. Filler:Paper filler (cable size 8 & 6 uses Polypropylene filler)
  5. Binder:Polyester flat thread binder tape for cable sizes larger than 2 AWG
  6. Overall Jacket:Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket

Resources

There are no downloadable resources for this product.