600V ROYAL® SOOW Cord Control with Black Jacket 90°C PCORD17

600 Volt 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation, Heat, Moisture and Oil Resistant Flexible CPE Jacket

Download Category Specifications
PDF Excel Table

Application & Features

Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications

Select a set of products below for more information:
Conductor
Size (AWG or kcmil) (mm2) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
More Options
18 AWG 18 AWG
6 6
16 16
492 12.50
142 211
5.5 5.5
6.59 6.59
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
18 AWG 18 AWG
7 7
16 16
488 12.40
140 208
4.5 4.5
6.59 6.59
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
18 AWG 18 AWG
8 8
16 16
521 13.23
164 244
4.5 4.5
6.59 6.59
BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
More Options
18 AWG 18 AWG
10 10
16 16
596 15.14
202 301
3.5 3.5
6.59 6.59
More Options
18 AWG 18 AWG
12 12
16 16
621 15.77
231 343
3.5 3.5
6.59 6.59
More Options
18 AWG 18 AWG
14 14
16 16
640 16.26
246 366
3.5 3.5
6.59 6.59
More Options
18 AWG 18 AWG
16 16
16 16
668 16.97
274 408
3.5 3.5
6.59 6.59
More Options
18 AWG 18 AWG
20 20
16 16
739 18.77
321 477
3.5 3.5
6.59 6.59
More Options
18 AWG 18 AWG
24 24
16 16
830 21.08
405 603
3 3
6.59 6.59
More Options
18 AWG 18 AWG
30 30
16 16
849 21.56
446 663
3 3
6.59 6.59
More Options
16 AWG 16 AWG
6 6
26 26
516 13.11
169 251
8 8
4.05 4.05
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
16 AWG 16 AWG
7 7
26 26
564 14.33
203 302
7 7
4.05 4.05
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
16 AWG 16 AWG
8 8
26 26
566 14.38
207 308
7 7
4.05 4.05
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
16 AWG 16 AWG
10 10
26 26
648 16.46
255 379
5 5
4.05 4.05
More Options
16 AWG 16 AWG
12 12
26 26
700 17.78
336 500
5 5
4.05 4.05
More Options
16 AWG 16 AWG
14 14
26 26
727 18.47
340 506
5 5
4.05 4.05
More Options
16 AWG 16 AWG
16 16
26 26
778 19.76
372 553
5 5
4.05 4.05
More Options
16 AWG 16 AWG
20 20
26 26
774 19.66
416 619
5 5
4.05 4.05
More Options
16 AWG 16 AWG
30 30
26 26
982 24.94
642 956
4.5 4.5
4.05 4.05
More Options
14 AWG 14 AWG
6 6
41 41
718 18.24
314 468
12 12
2.55 2.55
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
14 AWG 14 AWG
7 7
41 41
712 18.08
320 477
10 10
2.55 2.55
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
More Options
14 AWG 14 AWG
8 8
41 41
730 18.54
339 504
10 10
2.55 2.55
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
14 AWG 14 AWG
10 10
41 41
770 19.56
404 601
7 7
2.55 2.55
More Options
14 AWG 14 AWG
12 12
41 41
883 22.43
477 710
7 7
2.55 2.55
More Options
14 AWG 14 AWG
16 16
41 41
1020 25.91
633 943
7 7
2.55 2.55
More Options
12 AWG 12 AWG
6 6
65 65
740 18.80
390 580
16 16
1.61 1.61
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
12 AWG 12 AWG
7 7
65 65
740 18.80
353 525
14 14
1.61 1.61
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
More Options
12 AWG 12 AWG
8 8
65 65
803 20.40
445 662
14 14
1.61 1.61
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
More Options
12 AWG 12 AWG
9 9
65 65
852 21.64
483 719
14 14
1.61 1.61
More Options
12 AWG 12 AWG
10 10
65 65
894 22.71
501 745
10 10
1.61 1.61
More Options
12 AWG 12 AWG
12 12
65 65
987 25.07
627 934
10 10
1.61 1.61
More Options
12 AWG 12 AWG
14 14
65 65
1035 26.29
705 1049
10 10
1.61 1.61
More Options
12 AWG 12 AWG
16 16
65 65
1089 27.66
810 1205
10 10
1.61 1.61
More Options
10 AWG 10 AWG
6 6
104 104
830 21.08
488 726
20 20
0.98 0.98
BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
More Options
10 AWG 10 AWG
7 7
104 104
840 21.34
520 774
17 17
0.98 0.98
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
More Options
10 AWG 10 AWG
12 12
104 104
1067 27.10
848 1262
12 12
0.98 0.98

Standards & References

  • UL 62
  • CSA Standard 22.2 No. 49
  • NEC 400
  • NEC 501.140 Class I Division 2
  • Passes CSA FT2 Flame Test
  • MSHA
  • Federal and Military Specification JC-580B
  • RoHS-2 (European Directive 2011/65/EU )

Construction

  1. Conductors: Class K stranded bare copper per ASTM B-174
  2. Insulation: EPDM
  3. Jacket: Black CPE (Other colors available upon request)