Southwire Type SJEOOW Flexible Cords are permitted for indoor and outdoor temporary power uses, portable industrial machinery, compressors, conveyors, and automated production equipment. Cords are suitable for use in temperatures between -50°C to maximum 105°C.
| Conductor | ||||||||
| Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
| More Options |
18 AWG
18 AWG
|
2
2
|
16
16
|
286
7.26
|
39
58
|
|
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
18 AWG
18 AWG
|
3
3
|
16
16
|
308
7.82
|
48
71
|
10
10
|
6.59
6.59
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
18 AWG
18 AWG
|
4
4
|
16
16
|
331
8.41
|
59
88
|
7
7
|
6.59
6.59
|
WHITE/BLACK/GREEN/RED
WHITE/BLACK/GREEN/RED
|
| More Options |
16 AWG
16 AWG
|
2
2
|
26
26
|
310
7.87
|
46
69
|
13
13
|
4.05
4.05
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
16 AWG
16 AWG
|
3
3
|
26
26
|
331
8.41
|
61
91
|
13
13
|
4.05
4.05
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
16 AWG
16 AWG
|
4
4
|
26
26
|
370
9.40
|
78
116
|
10
10
|
4.05
4.05
|
BLACK/WHITE/GREEN/RED
BLACK/WHITE/GREEN/RED
|
| More Options |
14 AWG
14 AWG
|
2
2
|
41
41
|
340
8.64
|
61
91
|
18
18
|
2.55
2.55
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
14 AWG
14 AWG
|
3
3
|
41
41
|
366
9.30
|
81
120
|
18
18
|
2.55
2.55
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
14 AWG
14 AWG
|
4
4
|
41
41
|
396
10.06
|
102
151
|
15
15
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
| More Options |
12 AWG
12 AWG
|
2
2
|
65
65
|
416
10.57
|
95
142
|
25
25
|
1.61
1.61
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
12 AWG
12 AWG
|
3
3
|
65
65
|
436
11.07
|
123
183
|
25
25
|
1.61
1.61
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
12 AWG
12 AWG
|
4
4
|
65
65
|
480
12.19
|
156
232
|
20
20
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
| More Options |
10 AWG
10 AWG
|
2
2
|
104
104
|
551
14.00
|
163
243
|
30
30
|
0.98
0.98
|
BLACK/WHITE
BLACK/WHITE
|
| More Options |
10 AWG
10 AWG
|
3
3
|
104
104
|
576
14.63
|
207
308
|
30
30
|
0.98
0.98
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
| More Options |
10 AWG
10 AWG
|
4
4
|
104
104
|
636
16.15
|
266
396
|
25
25
|
0.98
0.98
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
* Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
^ Color Sequence: Black, Red
! White PVC jacket
** Not a Federal and Military Specification JC-580B
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.