Southwire Type W cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications per NEC Article 400. Suitable for continuous submersion in water ideal for submersible pumps. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Approved for use per the NEC® as Type RHH/RHW-2 90°C wet or dry. Meets FT-1 and FT-5 Flame Tests.
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (inches) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
| More Options |
8 AWG
8 AWG
|
1
1
|
168
168
|
0.145
0.37
|
60
1.52
|
83
2.11
|
0.465
1.18
|
141
210
|
| More Options |
4 AWG
4 AWG
|
1
1
|
427
427
|
0.235
0.60
|
60
1.52
|
105
2.67
|
0.592
1.50
|
267
397
|
| More Options |
2 AWG
2 AWG
|
1
1
|
259
259
|
0.291
0.74
|
60
1.52
|
105
2.67
|
0.686
1.74
|
366
545
|
| More Options |
1 AWG
1 AWG
|
1
1
|
259
259
|
0.3
0.76
|
80
2.03
|
105
2.67
|
0.726
1.84
|
441
656
|
| More Options |
1/0 AWG
1/0 AWG
|
1
1
|
259
259
|
0.379
0.96
|
80
2.03
|
105
2.67
|
0.779
1.98
|
530
789
|
| More Options |
2/0 AWG
2/0 AWG
|
1
1
|
324
324
|
0.4
1.02
|
80
2.03
|
105
2.67
|
0.848
2.15
|
637
948
|
| More Options |
3/0 AWG
3/0 AWG
|
1
1
|
418
418
|
0.48
1.22
|
80
2.03
|
105
2.67
|
0.864
2.19
|
758
1128
|
| More Options |
4/0 AWG
4/0 AWG
|
1
1
|
532
532
|
0.53
1.35
|
80
2.03
|
105
2.67
|
0.921
2.34
|
912
1357
|
| More Options |
250 KCMIL
250 KCMIL
|
1
1
|
608
608
|
0.605
1.54
|
95
2.41
|
105
2.67
|
1.031
2.62
|
1079
1606
|
| More Options |
350 KCMIL
350 KCMIL
|
1
1
|
893
893
|
0.67
1.70
|
95
2.41
|
105
2.67
|
1.13
2.87
|
1434
2134
|
| More Options |
500 KCMIL
500 KCMIL
|
1
1
|
1221
1221
|
0.858
2.18
|
95
2.41
|
105
2.67
|
1.274
3.24
|
1923
2862
|
| Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
| More Options |
8 AWG
8 AWG
|
0.654
0.97
|
0.812
1.21
|
0.052
0.08
|
132
59.87
|
1.9
4.83
|
50
50
|
55
55
|
| More Options |
4 AWG
4 AWG
|
0.263
0.39
|
0.326
0.49
|
0.048
0.07
|
333
151.05
|
2.4
6.10
|
85
85
|
95
95
|
| More Options |
2 AWG
2 AWG
|
0.166
0.25
|
0.206
0.31
|
0.045
0.07
|
530
240.40
|
2.7
6.86
|
115
115
|
130
130
|
| More Options |
1 AWG
1 AWG
|
0.132
0.20
|
0.164
0.24
|
0.046
0.07
|
669
303.45
|
2.9
7.37
|
130
130
|
145
145
|
| More Options |
1/0 AWG
1/0 AWG
|
0.105
0.16
|
0.130
0.19
|
0.044
0.07
|
844
382.83
|
3.1
7.87
|
150
150
|
170
170
|
| More Options |
2/0 AWG
2/0 AWG
|
0.084
0.13
|
0.104
0.15
|
0.043
0.06
|
1064
482.62
|
3.4
8.64
|
175
175
|
195
195
|
| More Options |
3/0 AWG
3/0 AWG
|
0.066
0.10
|
0.082
0.12
|
0.042
0.06
|
1342
608.72
|
3.5
8.89
|
200
200
|
225
225
|
| More Options |
4/0 AWG
4/0 AWG
|
0.053
0.08
|
0.066
0.10
|
0.041
0.06
|
1692
767.48
|
3.7
9.40
|
230
230
|
260
260
|
| More Options |
250 KCMIL
250 KCMIL
|
0.045
0.07
|
0.056
0.08
|
0.041
0.06
|
2000
907.18
|
5.2
13.21
|
255
255
|
290
290
|
| More Options |
350 KCMIL
350 KCMIL
|
0.032
0.05
|
0.041
0.06
|
0.040
0.06
|
2800
1270.06
|
5.6
14.22
|
310
310
|
350
350
|
| More Options |
500 KCMIL
500 KCMIL
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
4000
1814.37
|
6.4
16.26
|
380
380
|
430
430
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.