SPEC 45252 CU 600/1000V XLPE Insulation PVC Jacket XHHW-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Type TC-ER Power Cable 600 or 1000 Volt Three Conductor Copper, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Polyvinyl Chloride (PVC) Jacket with 1 Copper Ground (Bare or Insulated). CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free.

Download Category Specifications
Excel Table

Application

Southwire’s 600 or 1000 Volt Type TC-ER power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free

Specifications

Select a set of products below for more information:
Conductor Ground Wire
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Size (AWG) No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity
480590
3 3
8 AWG 8 AWG
7 7
45 1.14
10 10
688 17.49
327 487
480608
3 3
6 AWG 6 AWG
7 7
45 1.14
8 8
782 19.88
467 695
480616
3 3
4 AWG 4 AWG
7 7
45 1.14
8 8
806 20.48
612 911
480624
3 3
2 AWG 2 AWG
7 7
45 1.14
6 6
982 24.95
928 1381
480632
3 3
1 AWG 1 AWG
19 19
55 1.40
6 6
1106 28.09
1142 1700
480640
3 3
1/0 AWG 1/0 AWG
19 19
55 1.40
6 6
1200 30.49
1417 2109
480657
3 3
2/0 AWG 2/0 AWG
19 19
55 1.40
6 6
1295 32.91
1724 2565
480665
3 3
3/0 AWG 3/0 AWG
19 19
55 1.40
4 4
1399 35.54
2065 3074
480673
3 3
4/0 AWG 4/0 AWG
19 19
55 1.40
4 4
1494 37.95
2503 3725
480681
3 3
250 KCMIL 250 KCMIL
37 37
65 1.65
4 4
1619 41.14
2941 4376
480707
3 3
350 KCMIL 350 KCMIL
37 37
65 1.65
3 3
1910 48.52
4127 6142
480723
3 3
500 KCMIL 500 KCMIL
37 37
65 1.65
2 2
2167 55.05
5702 8485
593173
3 3
600 KCMIL 600 KCMIL
61 61
80 2.03
3/0 3/0
2417 61.41
7287 10844
554410
3 3
750 KCMIL 750 KCMIL
61 61
80 2.03
1 1
2694 68.44
8623 12833

Standards & References

  • ASTM B3: Soft or Annealed Copper Wire
  • ASTM B8: Concentric-Lay-Stranded Copper Conductors
  • UL 44: Thermoset-Insulated Wires and Cables
  • UL 1277: Electrical Power and Control Tray Cables
  • UL 1685: FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679: Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658: (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 383: Flame Test (70,000 btu)
  • IEEE 1202: FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  • Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  • Insulation: Cross Linked Polyethylene (XLPE) Type XHHW-2
  • Grounding Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8. (When present, cable conductor sizes 8 & 6 AWG have an insulated green ground)
  • Filler: Paper filler (cable size 8 & 6 uses Polypropylene filler)
  • Binder: Polyester flat thread binder tape for cable sizes larger than 2 AWG
  • Overall Jacket: Polyvinyl Chloride (PVC) Jacket