SPEC 45251 CU 600V PVC-Nylon Insulation PVC Jacket THHN/THWN-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Type TC-ER Power Cable 600Volt Three Conductor Copper, Polyvinyl Chloride (PVC) with nylon layer insulation THHN Polyvinyl Chloride (PVC) Jacket with 1 Bare CU Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Download Category Specifications
Excel Table

Application

Southwire’s 600 Volt Type TC-ER power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free

Specifications

Select a set of products below for more information:
Conductor Ground Wire
No. of Conductors Size (AWG or kcmil) (mm2) No. of Strands Insulation Thickness (mils) (mm) Size (AWG) No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity
443390
3 3
8 AWG 8 AWG
7 7
30 0.76
10 10
640 16.26
307 457
443408
3 3
6 AWG 6 AWG
7 7
30 0.76
8 8
734 18.65
451 672
443416
3 3
4 AWG 4 AWG
7 7
40 1.02
8 8
813 20.66
623 927
443424
3 3
2 AWG 2 AWG
7 7
40 1.02
6 6
986 25.06
971 1446
443432
3 3
1 AWG 1 AWG
19 19
50 1.27
6 6
1116 28.35
1181 1757
443440
3 3
1/0 AWG 1/0 AWG
19 19
50 1.27
6 6
1183 30.07
1407 2094
443457
3 3
2/0 AWG 2/0 AWG
19 19
50 1.27
6 6
1278 32.48
1689 2514
443465
3 3
3/0 AWG 3/0 AWG
19 19
50 1.27
4 4
1386 35.23
2101 3126
443473
3 3
4/0 AWG 4/0 AWG
19 19
50 1.27
4 4
1481 37.64
2603 3874
443481
3 3
250 KCMIL 250 KCMIL
37 37
60 1.52
4 4
1659 42.14
3091 4600
443507
3 3
350 KCMIL 350 KCMIL
37 37
60 1.52
3 3
1941 49.31
4187 6230
443523
3 3
500 KCMIL 500 KCMIL
37 37
60 1.52
2 2
2168 55.07
5734 8533
604777
3 3
600 KCMIL 600 KCMIL
61 61
70 1.78
2 2
2388 60.67
6785 10097
602094
3 3
750 KCMIL 750 KCMIL
61 61
70 1.78
1 1
2665 67.69
8668 12899

Standards & References

  • ASTM B3: Soft or Annealed Copper Wire
  • ASTM B8: Concentric-Lay-Stranded Copper Conductors
  • UL 83: Thermoplastic Insulated Wires and Cables
  • UL 1277: Electrical Power and Control Tray Cables
  • UL 1685: Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679: Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658: (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202: FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  • Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  • Insulation: Polyvinyl Chloride (PVC) with nylon layer Type THHN/THWN
  • Grounding Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (cable size 8 & 6 has insulated green ground)
  • Filler: Paper filler (cable size 8 & 6 uses Polypropylene filler)
  • Binder: Polyester flat thread binder tape for cable sizes larger than 2 AWG
  • Overall Jacket: Polyvinyl Chloride (PVC) Jacket