Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. VW-1 Rated #14 - #10 AWG. Sunlight Resistant - For Direct Burial - Silicone Free
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
591931 |
2
2
|
16 AWG
16 AWG
|
7
7
|
|
|
|
332
8.43
|
52
77
|
|
591932 |
3
3
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
351
8.92
|
67
99
|
|
591933 |
4
4
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
382
9.70
|
83
123
|
|
591934 |
5
5
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
415
10.55
|
100
149
|
|
591935 |
7
7
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
451
11.46
|
129
192
|
|
591936 |
9
9
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
555
14.10
|
178
266
|
|
591937 |
12
12
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
618
15.70
|
225
336
|
|
591944 |
2
2
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
366
9.30
|
66
98
|
|
591947 |
3
3
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
388
9.86
|
86
128
|
|
591948 |
4
4
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
423
10.74
|
108
161
|
|
591949 |
5
5
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
461
11.71
|
130
193
|
|
591950 |
7
7
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
502
12.75
|
171
254
|
|
591951 |
9
9
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
616
15.65
|
233
346
|
|
591952 |
12
12
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
692
17.58
|
299
446
|
|
591953 |
15
15
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
560
14.22
|
413
615
|
|
591954 |
19
19
|
14 AWG
14 AWG
|
7
7
|
30
0.76
|
|
|
560
14.22
|
413
615
|
|
591959 |
2
2
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
404
10.26
|
87
129
|
|
591960 |
3
3
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
466
11.84
|
117
174
|
|
591962 |
4
4
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
469
11.91
|
147
219
|
|
591963 |
5
5
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
543
13.79
|
198
295
|
|
591964 |
7
7
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
589
14.96
|
254
378
|
|
591965 |
9
9
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
589
14.96
|
307
457
|
|
591966 |
12
12
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
466
11.84
|
412
613
|
|
591968 |
19
19
|
12 AWG
12 AWG
|
7
7
|
30
0.76
|
|
|
934
23.72
|
660
982
|
|
591973 |
2
2
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
448
11.38
|
117
174
|
|
591974 |
3
3
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
476
12.09
|
161
239
|
|
591976 |
4
4
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
560
14.22
|
225
335
|
|
591977 |
5
5
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
602
15.29
|
268
398
|
|
591978 |
7
7
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
655
16.64
|
356
529
|
|
591979 |
9
9
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
765
19.43
|
451
671
|
|
591980 |
12
12
|
10 AWG
10 AWG
|
7
7
|
30
0.76
|
|
|
899
22.83
|
619
922
|
|
591938 |
15
15
|
16 AWG
16 AWG
|
7
7
|
30
0.76
|
|
|
684
17.39
|
273
407
|
|