Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), aerially supported by a messenger and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemicals, oils and acids and are flame retardant.
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
953638 |
1
1
|
2 AWG
2 AWG
|
7
7
|
220
5.59
|
|
|
995
25.27
|
640
953
|
|
955104 |
1
1
|
1 AWG
1 AWG
|
19
19
|
220
5.59
|
|
|
1040
26.42
|
723
1076
|
|
955989 |
1
1
|
1/0 AWG
1/0 AWG
|
19
19
|
220
5.59
|
|
|
1080
27.43
|
816
1215
|
|
955997 |
1
1
|
2/0 AWG
2/0 AWG
|
19
19
|
220
5.59
|
|
|
1124
28.55
|
930
1384
|
|
956003 |
1
1
|
3/0 AWG
3/0 AWG
|
19
19
|
220
5.59
|
|
|
1174
29.82
|
1070
1592
|
|
956011 |
1
1
|
4/0 AWG
4/0 AWG
|
19
19
|
220
5.59
|
|
|
1230
31.24
|
1243
1849
|
|
956029 |
1
1
|
250 KCMIL
250 KCMIL
|
37
37
|
220
5.59
|
|
|
1284
32.61
|
1399
2082
|
|
956037 |
1
1
|
350 KCMIL
350 KCMIL
|
37
37
|
220
5.59
|
|
|
1387
35.23
|
1775
2642
|
|
956045 |
1
1
|
500 KCMIL
500 KCMIL
|
37
37
|
220
5.59
|
|
|
1492
37.90
|
2308
3434
|
|
643755 |
1
1
|
600 KCMIL
600 KCMIL
|
61
61
|
220
5.59
|
|
|
1576
40.03
|
2677
3983
|
|
956052 |
1
1
|
750 KCMIL
750 KCMIL
|
61
61
|
220
5.59
|
|
|
1764
44.81
|
3323
4945
|
|
956060 |
1
1
|
1000 KCMIL
1000 KCMIL
|
61
61
|
220
5.59
|
|
|
1913
48.59
|
4203
6254
|
|
581886 |
1
1
|
1250 KCMIL
1250 KCMIL
|
91
91
|
220
5.59
|
|
|
2080
52.83
|
5109
7603
|
|
567443 |
1
1
|
1500 KCMIL
1500 KCMIL
|
91
91
|
220
5.59
|
|
|
2230
56.64
|
6006
8939
|
|
550811 |
1
1
|
2000 KCMIL
2000 KCMIL
|
127
127
|
220
5.59
|
|
|
2443
62.05
|
7716
11483
|
|