Southwire Type SOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights welding leads, marine dockside power, power extensions and mining applications.
Conductor | ||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
570040 |
18 AWG
18 AWG
|
2
2
|
16
16
|
353
8.97
|
87
130
|
|
|
BLACK/WHITE
BLACK/WHITE
|
570046 |
18 AWG
18 AWG
|
3
3
|
16
16
|
370
9.40
|
99
147
|
|
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
570047 |
18 AWG
18 AWG
|
4
4
|
16
16
|
398
10.11
|
120
178
|
|
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
570053 |
18 AWG
18 AWG
|
8
8
|
16
16
|
548
13.92
|
200
297
|
|
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
576078 |
18 AWG
18 AWG
|
10
10
|
16
16
|
616
15.65
|
245
364
|
|
|
|
570035 |
18 AWG
18 AWG
|
12
12
|
16
16
|
651
16.54
|
276
411
|
|
|
|
571439 |
16 AWG
16 AWG
|
2
2
|
26
26
|
385
9.78
|
116
173
|
|
|
BLACK/WHITE
BLACK/WHITE
|
570027 |
16 AWG
16 AWG
|
4
4
|
26
26
|
445
11.30
|
148
221
|
|
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
570031 |
16 AWG
16 AWG
|
8
8
|
26
26
|
561
14.25
|
243
361
|
|
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
570012 |
16 AWG
16 AWG
|
12
12
|
26
26
|
729
18.52
|
363
540
|
|
|
|
570013 |
16 AWG
16 AWG
|
16
16
|
26
26
|
793
20.14
|
442
658
|
|
|
|
571277 |
14 AWG
14 AWG
|
3
3
|
41
41
|
565
14.36
|
210
313
|
|
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
570008 |
14 AWG
14 AWG
|
4
4
|
41
41
|
609
15.47
|
244
363
|
|
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
571316 |
12 AWG
12 AWG
|
2
2
|
65
65
|
600
15.24
|
233
346
|
|
|
BLACK/WHITE
BLACK/WHITE
|
571400 |
12 AWG
12 AWG
|
3
3
|
65
65
|
629
16.00
|
268
399
|
|
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
569989 |
12 AWG
12 AWG
|
4
4
|
65
65
|
677
17.21
|
322
480
|
|
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
587862 |
14 AWG
14 AWG
|
2
2
|
41
41
|
535
13.59
|
175
260
|
|
|
BLACK/WHITE
BLACK/WHITE
|