Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.
Conductor | ||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
558235 |
18 AWG
18 AWG
|
5
5
|
16
16
|
465
11.81
|
127
189
|
5.5
5.5
|
6.59
6.59
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
558100 |
16 AWG
16 AWG
|
3
3
|
26
26
|
395
10.03
|
96
143
|
13
13
|
4.05
4.05
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
558101 |
16 AWG
16 AWG
|
4
4
|
26
26
|
420
10.67
|
111
165
|
10
10
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
558231 |
16 AWG
16 AWG
|
5
5
|
26
26
|
514
13.06
|
167
249
|
8
8
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
558099 |
14 AWG
14 AWG
|
3
3
|
41
41
|
530
13.46
|
169
252
|
18
18
|
2.55
2.55
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
558102 |
14 AWG
14 AWG
|
4
4
|
41
41
|
570
14.48
|
206
307
|
15
15
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
558147 |
14 AWG
14 AWG
|
5
5
|
41
41
|
655
16.64
|
264
392
|
12
12
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
558094 |
12 AWG
12 AWG
|
3
3
|
65
65
|
608
15.44
|
230
342
|
25
25
|
1.61
1.61
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
558095 |
12 AWG
12 AWG
|
4
4
|
65
65
|
650
16.51
|
273
406
|
20
20
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
558104 |
12 AWG
12 AWG
|
5
5
|
65
65
|
698
17.73
|
293
436
|
16
16
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
558097 |
10 AWG
10 AWG
|
3
3
|
104
104
|
665
16.89
|
297
442
|
30
30
|
0.98
0.98
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
558096 |
10 AWG
10 AWG
|
4
4
|
104
104
|
715
18.16
|
350
521
|
25
25
|
0.98
0.98
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
558103 |
10 AWG
10 AWG
|
5
5
|
104
104
|
792
20.12
|
453
674
|
20
20
|
0.98
0.98
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
560039 |
8 AWG
8 AWG
|
3
3
|
133
133
|
848
21.54
|
427
635
|
40
40
|
0.63
0.63
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
630726 |
8 AWG
8 AWG
|
4
4
|
133
133
|
954
24.23
|
596
887
|
35
35
|
0.63
0.63
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
596961 |
8 AWG
8 AWG
|
5
5
|
133
133
|
1036
26.31
|
717
1067
|
28
28
|
0.63
0.63
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
560041 |
6 AWG
6 AWG
|
3
3
|
133
133
|
990
25.15
|
675
1005
|
55
55
|
0.4
0.4
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
560042 |
6 AWG
6 AWG
|
4
4
|
133
133
|
1075
27.31
|
830
1235
|
45
45
|
0.4
0.4
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
562068 |
6 AWG
6 AWG
|
5
5
|
133
133
|
1192
30.28
|
1030
1533
|
36
36
|
0.4
0.4
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
570054 |
4 AWG
4 AWG
|
3
3
|
427
427
|
1137
28.88
|
893
1329
|
70
70
|
0.25
0.25
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
560925 |
4 AWG
4 AWG
|
4
4
|
427
427
|
1257
31.93
|
1156
1721
|
60
60
|
0.25
0.25
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
562067 |
4 AWG
4 AWG
|
5
5
|
427
427
|
1395
35.45
|
1400
2084
|
48
48
|
0.25
0.25
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|
560928 |
2 AWG
2 AWG
|
4
4
|
168
168
|
1480
37.59
|
1723
2564
|
80
80
|
0.016
0.016
|
BLACK/WHITE/RED/GREEN
BLACK/WHITE/RED/GREEN
|
562065 |
2 AWG
2 AWG
|
5
5
|
168
168
|
1716
43.59
|
2006
2985
|
64
64
|
0.16
0.16
|
BLACK/WHITE/RED/GREEN/ORANGE
BLACK/WHITE/RED/GREEN/ORANGE
|