HDFPC-DLO is a 2kV flexible power cable with a variety of possible applications such as but not limited to: Drilling rigs, railroad and transit car wiring, mining and other industrial equipment, and as flexible motor leads and wind turbine applications. The cable is suited for use in wet and dry areas, conduits, ducts, troughs, trays, and where superior electrical properties are desired. HDFPC-DLO is oil, heat, flame, abrasion, and sunlight resistant. Approved for use per the NEC® as Type RHH/RHW-2 and per the CE Code as 2kV Type RW90. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Sizes 1/0 and Larger Rated For CT Use.
Conductor | Allowable Ampacities+ | Resistance | ||||||||||
Size (AWG or kcmil) (mm2) | No. of Strands | Nom. OD (Conductor) (mils) (mm) | Nom. OD (mils) (mm) | Nom. OD (Over Ins.) (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity at 60C | Allowable Ampacity at 75C | Allowable Ampacity at 90C | Insulation Thickness (mils) (mm) | Nom. DC Resistance (Conductor) | AC Resistance at 90°C | |
571253 |
12 AWG
12 AWG
|
19
19
|
|
210
5.33
|
|
36
54
|
|
25
25
|
30
30
|
|
1.69
1.69
|
|
560057 |
10 AWG
10 AWG
|
19
19
|
|
265
6.74
|
|
59
87
|
|
35
35
|
40
40
|
|
1.04
1.04
|
|
167014 |
8 AWG
8 AWG
|
41
41
|
|
330
8.38
|
|
91
135
|
|
50
50
|
55
55
|
|
0.654
0.654
|
|
167015 |
6 AWG
6 AWG
|
65
65
|
|
370
9.40
|
|
127
189
|
|
65
65
|
75
75
|
|
0.419
0.419
|
|
167017 |
4 AWG
4 AWG
|
105
105
|
|
440
11.18
|
|
196
292
|
|
85
85
|
95
95
|
|
0.263
0.263
|
|
167019 |
2 AWG
2 AWG
|
161
161
|
|
500
12.70
|
|
282
420
|
|
115
115
|
130
130
|
|
0.166
0.166
|
|
167021 |
1/0 AWG
1/0 AWG
|
266
266
|
|
645
16.38
|
|
451
671
|
|
150
150
|
170
170
|
|
0.105
0.105
|
|
167022 |
2/0 AWG
2/0 AWG
|
342
342
|
|
690
17.53
|
|
566
843
|
|
175
175
|
195
195
|
|
0.0834
0.0834
|
|
167023 |
3/0 AWG
3/0 AWG
|
418
418
|
|
760
19.30
|
|
676
1006
|
|
200
200
|
225
225
|
|
0.0662
0.0662
|
|
167024 |
4/0 AWG
4/0 AWG
|
532
532
|
|
815
20.70
|
|
815
1212
|
|
230
230
|
260
260
|
|
0.0525
0.0525
|
|
167026 |
262.2 KCMIL
262.2 KCMIL
|
646
646
|
|
915
23.24
|
|
974
1450
|
|
267
267
|
304
304
|
|
0.0426
0.0426
|
|
167027 |
313.3 KCMIL
313.3 KCMIL
|
779
779
|
|
980
24.89
|
|
1140
1696
|
|
298
298
|
332
332
|
|
0.0357
0.0357
|
|
167029 |
373.7 KCMIL
373.7 KCMIL
|
931
931
|
|
1040
26.42
|
|
1344
2000
|
|
323
323
|
365
365
|
|
0.03
0.03
|
|
167030 |
444.4 KCMIL
444.4 KCMIL
|
1121
1121
|
|
1105
28.07
|
|
1654
2461
|
|
358
358
|
405
405
|
|
0.0252
0.0252
|
|
167031 |
535.3 KCMIL
535.3 KCMIL
|
1330
1330
|
|
1212
30.78
|
|
1892
2816
|
|
394
394
|
446
446
|
|
0.0209
0.0209
|
|
167032 |
646.4 KCMIL
646.4 KCMIL
|
1628
1628
|
|
1290
32.77
|
|
2292
3411
|
|
439
439
|
496
496
|
|
0.0174
0.0174
|
|
167033 |
777.7 KCMIL
777.7 KCMIL
|
1924
1924
|
|
1405
35.69
|
|
2719
4046
|
|
483
483
|
543
543
|
|
0.0146
0.0146
|
|
167035 |
1111 KCMIL
1111 KCMIL
|
2745
2745
|
|
1640
41.66
|
|
4162
6193
|
|
570
570
|
648
648
|
|
0.012
0.012
|
|