Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.
Conductor | ||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
558236 |
18 AWG
18 AWG
|
6
6
|
16
16
|
488
12.40
|
139
207
|
5.5
5.5
|
6.59
6.59
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
558237 |
18 AWG
18 AWG
|
7
7
|
16
16
|
488
12.40
|
140
208
|
4.5
4.5
|
6.59
6.59
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
558238 |
18 AWG
18 AWG
|
8
8
|
16
16
|
521
13.23
|
164
244
|
4.5
4.5
|
6.59
6.59
|
BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
570034 |
18 AWG
18 AWG
|
10
10
|
16
16
|
596
15.14
|
201
299
|
3.5
3.5
|
6.59
6.59
|
|
570037 |
18 AWG
18 AWG
|
12
12
|
16
16
|
605
15.37
|
218
324
|
3.5
3.5
|
6.59
6.59
|
|
598302 |
18 AWG
18 AWG
|
14
14
|
16
16
|
640
16.26
|
246
366
|
3.5
3.5
|
6.59
6.59
|
|
570039 |
18 AWG
18 AWG
|
16
16
|
16
16
|
668
16.97
|
274
408
|
3.5
3.5
|
6.59
6.59
|
|
570042 |
18 AWG
18 AWG
|
20
20
|
16
16
|
739
18.77
|
321
477
|
3.5
3.5
|
6.59
6.59
|
|
570043 |
18 AWG
18 AWG
|
24
24
|
16
16
|
830
21.08
|
398
592
|
3
3
|
6.59
6.59
|
|
571692 |
18 AWG
18 AWG
|
30
30
|
16
16
|
849
21.56
|
446
663
|
3
3
|
6.59
6.59
|
|
558232 |
16 AWG
16 AWG
|
6
6
|
26
26
|
516
13.11
|
169
251
|
8
8
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
558233 |
16 AWG
16 AWG
|
7
7
|
26
26
|
564
14.33
|
203
302
|
7
7
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
558234 |
16 AWG
16 AWG
|
8
8
|
26
26
|
515
13.08
|
192
285
|
7
7
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
560526 |
16 AWG
16 AWG
|
10
10
|
26
26
|
648
16.46
|
277
412
|
5
5
|
4.05
4.05
|
|
560527 |
16 AWG
16 AWG
|
12
12
|
26
26
|
684
17.37
|
321
478
|
5
5
|
4.05
4.05
|
|
598305 |
16 AWG
16 AWG
|
14
14
|
26
26
|
727
18.47
|
340
506
|
5
5
|
4.05
4.05
|
|
560528 |
16 AWG
16 AWG
|
16
16
|
26
26
|
778
19.76
|
372
553
|
5
5
|
4.05
4.05
|
|
570018 |
16 AWG
16 AWG
|
20
20
|
26
26
|
745
18.92
|
397
591
|
5
5
|
4.05
4.05
|
|
570019 |
16 AWG
16 AWG
|
24
24
|
26
26
|
893
22.68
|
500
744
|
4.5
4.5
|
4.05
4.05
|
|
570026 |
16 AWG
16 AWG
|
30
30
|
26
26
|
982
24.94
|
647
963
|
4.5
4.5
|
4.05
4.05
|
|
558149 |
14 AWG
14 AWG
|
6
6
|
41
41
|
664
16.87
|
335
499
|
12
12
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
558150 |
14 AWG
14 AWG
|
7
7
|
41
41
|
712
18.08
|
316
470
|
10
10
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
558230 |
14 AWG
14 AWG
|
8
8
|
41
41
|
730
18.54
|
349
519
|
10
10
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
569994 |
14 AWG
14 AWG
|
10
10
|
41
41
|
770
19.56
|
404
601
|
7
7
|
2.55
2.55
|
|
571270 |
14 AWG
14 AWG
|
12
12
|
41
41
|
883
22.43
|
477
710
|
7
7
|
2.55
2.55
|
|
569995 |
14 AWG
14 AWG
|
14
14
|
41
41
|
980
24.89
|
595
886
|
7
7
|
2.55
2.55
|
|
569997 |
14 AWG
14 AWG
|
16
16
|
41
41
|
1020
25.91
|
633
943
|
7
7
|
2.55
2.55
|
|
569999 |
14 AWG
14 AWG
|
24
24
|
41
41
|
1175
29.85
|
868
1291
|
6
6
|
2.55
2.55
|
|
558144 |
12 AWG
12 AWG
|
6
6
|
65
65
|
740
18.80
|
390
580
|
16
16
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
558145 |
12 AWG
12 AWG
|
7
7
|
65
65
|
740
18.80
|
353
525
|
14
14
|
1.61
1.61
|
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
558146 |
12 AWG
12 AWG
|
8
8
|
65
65
|
796
20.22
|
429
638
|
14
14
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
571397 |
12 AWG
12 AWG
|
9
9
|
65
65
|
852
21.64
|
483
719
|
14
14
|
1.61
1.61
|
|
569981 |
12 AWG
12 AWG
|
10
10
|
65
65
|
894
22.71
|
501
745
|
10
10
|
1.61
1.61
|
|
569982 |
12 AWG
12 AWG
|
12
12
|
65
65
|
987
25.07
|
627
934
|
10
10
|
1.61
1.61
|
|
598307 |
12 AWG
12 AWG
|
14
14
|
65
65
|
1035
26.29
|
705
1049
|
10
10
|
1.61
1.61
|
|
598308 |
12 AWG
12 AWG
|
16
16
|
65
65
|
1089
27.66
|
810
1205
|
10
10
|
1.61
1.61
|
|
569983 |
12 AWG
12 AWG
|
20
20
|
65
65
|
1200
30.48
|
940
1398
|
10
10
|
1.61
1.61
|
|
569987 |
12 AWG
12 AWG
|
37
37
|
65
65
|
1536
39.01
|
1561
2322
|
8
8
|
1.61
1.61
|
|
569979 |
10 AWG
10 AWG
|
6
6
|
104
104
|
830
21.08
|
488
726
|
20
20
|
0.98
0.98
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
569980 |
10 AWG
10 AWG
|
7
7
|
104
104
|
840
21.34
|
520
773
|
17
17
|
0.98
0.98
|
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
570006 |
10 AWG
10 AWG
|
12
12
|
104
104
|
1067
27.10
|
848
1262
|
12
12
|
0.98
0.98
|
|