SPEC: 48001

CU 600V LSZH XHHW-2 SOLONONplus™

SOLONONplus™ 600Volt Single Conductor Copper Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Insulation Type XHHW-2

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt SOLONONplus™ Type XHHW-2 cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, and aerially when supported by a messenger. These cables are ideal for use in establishments where low smoke and low acid emissions are desired for public safety and health and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

a. The conductors are available in tinned and flexible copper stranding upon request.
b. NEC compliant
c. The halogen content is less than 0.2% and Acid gas less than 2.0%
d. Passes UL VW-1 # 8 AWG and larger
e. 70,000 BTU/Hr. Vertical Flame Test
f. UL listed for CT use on 1/0 and Larger
g. UL listed FT4/IEEE 1202 and ST-1 (#8 and larger)
h. -40°C Cold impact and cold bend
i. Oil Resistant I and II
j. UV/Sunlight resistant black color
k. Color Available upon request

Specifications

Select a set of products below for more information:
Cond. Size Cond. Strands Strand Class Conductor Number Insulation Thickness (mils) (mm) Jacket Color Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) DC Resistance at 25C (ohms/1000') (ohms/km) Max Pull Tension (lbs) (kg)
More Options
14 AWG 14 AWG
7 7
B B
1 1
30 0.76
BK BK
0.133 0.34
18 27
2.631 3.92
More Options
12 AWG 12 AWG
Solid Solid
Solid Solid
1 1
30 0.76
BK BK
0.144 0.37
26 39
1.662 2.47
More Options
10 AWG 10 AWG
Solid Solid
Solid Solid
1 1
30 0.76
BK BK
0.165 0.42
39 58
1.040 1.55
More Options
8 AWG 8 AWG
7 7
B B
1 1
45 1.14
BK BK
0.236 0.60
67 100
0.653 0.97
132 59.87
More Options
6 AWG 6 AWG
7 7
B B
1 1
45 1.14
BK BK
0.272 0.69
100 149
0.411 0.61
209 94.80
More Options
4 AWG 4 AWG
7 7
B B
1 1
45 1.14
BK BK
0.319 0.81
152 226
0.258 0.38
333 151.05
More Options
3 AWG 3 AWG
7 7
B B
1 1
45 1.14
BK BK
0.346 0.88
188 280
0.205 0.31
420 190.51
More Options
2 AWG 2 AWG
7 7
B B
1 1
45 1.14
BK BK
0.371 0.94
233 347
0.162 0.24
530 240.40
More Options
1 AWG 1 AWG
19 19
B B
1 1
55 1.40
BK BK
0.438 1.11
299 445
0.128 0.19
669 303.45
More Options
1/0 AWG 1/0 AWG
19 19
B B
1 1
55 1.40
BK BK
0.478 1.21
371 552
0.102 0.15
844 382.83
More Options
2/0 AWG 2/0 AWG
19 19
B B
1 1
55 1.40
BK BK
0.522 1.33
461 686
0.081 0.12
1064 482.62
More Options
250 KCMIL 250 KCMIL
37 37
B B
1 1
65 1.65
BK BK
0.678 1.72
849 1263
0.043 0.06
2000 907.18
More Options
600 KCMIL 600 KCMIL
61 61
B B
1 1
80 2.03
BK BK
1.034 2.63
2000 2976
0.018 0.03
4800 2177.24

^ # 6AWG Stock Number 679070 is Tinned Copper Conductor

Size (Strand) Black Red Blue White Brown Orange Yellow Gray Green Purple
14 (Solid) 14 (Solid)
649593
12 (Solid) 12 (Solid)
599254
599255 599255
599256 599256
599253 599253
599258 599258
599259 599259
599260 599260
599257 599257
599252 599252
647516 647516
10 (Solid) 10 (Solid)
599263
599264 599264
599265 599265
599262 599262
599281 599281
599282 599282
599283 599283
599280 599280
599261 599261
14 (7) 14 (7)
647361
643917 643917
12 (7) 12 (7)
677425 677425
646526 646526
646527 646527
646528 646528
649601
646529 646529
10 (7) 10 (7)
646542
646530 646530
646531 646531
646532 646532
646533 646533
8 (7) 8 (7)
599328
599331 599331
599329 599329
599333 599333
599335 599335
599336 599336
599334 599334
599330 599330
6 (7) 6 (7)
679070 679070
599340 599340
599338 599338
599341 599341
599342 599342
599344 599344
599345 599345
599343 599343
599339 599339
4 (7) 4 (7)
599346
599349 599349
599347 599347
599350 599350
599351 599351
599353 599353
599354 599354
599352 599352
599348 599348
3 (7) 3 (7)
641691
2 (7) 2 (7)
599355
599358 599358
599356 599356
599359 599359
599360 599360
599507 599507
599508 599508
599505 599505
599357 599357
1 (19) 1 (19)
643752
1/0 (19) 1/0 (19)
641693
641694 641694
2/0 (19) 2/0 (19)
599509
679228 679228
4/0 (19) 4/0 (19)
599519 599519
250 (37) 250 (37)
641699
679131 679131
300 (37) 300 (37)
649645 649645
500 (37) 500 (37)
641702 641702
600 (61) 600 (61)
641703

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B170 Oxygen Free Electrolytic Copper (available upon request)
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2885 Acid Gas, Acidity and conductivity of combusted materials and assessment of halogens
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA T-33-655/MIL-C-24643 Low Smoke Halogen Free (LSHF) Polymeric Jackets
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • ISO 9001 Quality management
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways

Construction

  1. Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation: SOLONONplus™ Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Type XHHW-2

Resources

There are no downloadable resources for this product.